OVERWATCH 108-157-01Recalls & reported problems

Spinal Elements · OVERWATCH® N Driver Inner Shaft · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840916134839), received between Dec 15, 2023 and Dec 15, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Unintended Movement” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unintended Movement1
  • Unintended System Motion1

Patient problems

  • Vertebral Fracture1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 15, 2023Unintended System Motion; Unintended Movement; Unintended System Motion; Unintended Movement

    REPORTEDLY DURING A TLIF SPINAL FUSION SURGERY WITH POSTERIOR FIXATION (L2- S1), A PEDICLE BONE SCREW FRACTURED/CRACKED THE PEDICLE BONE L3 ON (B)(6) 2023. ALLEGEDLY THE DRIVER OR DRIVER SLEEVE WAS BENT. THE DEVICE WOBBLED AND HAD A DIFFERENT TRAJECTORY AND/OR DIFFERENT STARTING POINT, WHEN ADVANCING THE SCREW. THIS CONDITION ALLEGED CAUSED A CRACKED/FRACTURE IN THE PEDICLE BONE. NO ADDITIONAL MEDICAL INTERVENTION WAS TAKEN. PATIENT IS ASYMPTOMATIC AND THERE IS NO PLAN FOR REVISION SURGERY.

    Patient problems: Vertebral Fracture

    MAUDE report 18340772 ↗