"1.5MM" SYSTEM 91-6104Recalls & reported problems

Biomet Microfixation, Inc · Class 2

All models of "1.5MM" SYSTEM (35)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00841036053734), received between Mar 8, 2019 and May 29, 2025 — classified as 6 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Fracture” (7 reports).

11 other recalls cover devices cleared under the same FDA submission (K121589, K121624, K953385); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 2 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture7
  • Device Handling Problem1
  • Difficult to Insert1

Patient problems

  • Foreign Body In Patient5
  • No Clinical Signs, Symptoms or Conditions3
  • Unspecified Infection1

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 29, 2025Fracture; Fracture

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A CRANIOTOMY PROCEDURE. DURING THE PROCEDURE, TWO SELF-DRILLING SCREWS FRACTURED AFTER BEING IMPLANTED IN THE CRANIAL REGION. THE FRACTURED DEVICES WERE RETAINED. DUE TO THE EVENT, THERE WAS A SMALL DELAY IN THE PROCEDURE. PATIENT EXPIRED FIVE DAYS POST PROCEDURE. THE PATIENT HAD CANCER AND UNDERWENT A CRANIOTOMY TO REMOVE A TUMOR. THE PATIENT SUFFERED A HEMATOMA THAT WAS NOT RELATED TO THE IMPLANTED PRODUCT AND THE SURGEON STATED THIS IS THE REASON THE PATIENT EXPIRED.

    Patient problems: Foreign Body In Patient

    MAUDE report 22106225 ↗
  • InjuryMay 29, 2025Fracture; Fracture

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A CRANIOTOMY PROCEDURE. DURING THE PROCEDURE, TWO SELF-DRILLING SCREWS FRACTURED AFTER BEING IMPLANTED IN THE CRANIAL REGION. THE FRACTURED DEVICES WERE RETAINED. DUE TO THE EVENT, THERE WAS A SMALL DELAY IN THE PROCEDURE. PATIENT EXPIRED FIVE DAYS POST PROCEDURE. THE PATIENT HAD CANCER AND UNDERWENT A CRANIOTOMY TO REMOVE A TUMOR. THE PATIENT SUFFERED A HEMATOMA THAT WAS NOT RELATED TO THE IMPLANTED PRODUCT AND THE SURGEON STATED THIS IS THE REASON THE PATIENT EXPIRED.

    Patient problems: Foreign Body In Patient

    MAUDE report 22106216 ↗
  • MalfunctionFeb 22, 2022Fracture; Fracture

    IT WAS REPORTED THAT THE SCREWS FRAGMENTED DURING IMPLANTATION. THE SURGEON REMOVED THE FRACTURED SCREWS DURING THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13578979 ↗
  • MalfunctionFeb 22, 2022Fracture; Fracture

    IT WAS REPORTED THAT THE SCREWS FRAGMENTED DURING IMPLANTATION. THE SURGEON REMOVED THE FRACTURED SCREWS DURING THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13578948 ↗
  • MalfunctionJan 7, 2022Difficult to Insert; Difficult to Insert

    IT WAS REPORTED WHEN THE SURGEON WENT TO IMPLANT THE SCREWS, THE TIP OF THE SCREW DID NOT INSERT CORRECTLY. THE SURGEON CHANGED OUT THE SCREWS AND PROCEEDED WITH THE CASE. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13192763 ↗
  • InjuryAug 16, 2021Fracture; Fracture

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Foreign Body In Patient

    MAUDE report 12329092 ↗
  • InjuryAug 16, 2021Fracture; Fracture

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Foreign Body In Patient

    MAUDE report 12329083 ↗
  • InjuryJul 5, 2019Fracture; Fracture

    THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. MULTIPLE ATTEMPTS WERE MADE TO OBTAIN INFORMATION REGARDING THE RETENTION OF THE FOREIGN BODY IN THE PATIENT, AND CONFLICTING INFORMATION WAS RECEIVED. THEREFORE, ZIMMER BIOMET CANNOT DETERMINE AT THIS TIME IF A FOREIGN BODY WAS RETAINED IN THE PATIENT'S BONE.

    Patient problems: Foreign Body In Patient

    MAUDE report 8765715 ↗
  • InjuryMar 8, 2019Device Handling Problem; Device Handling Problem

    THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION.

    Patient problems: Unspecified Infection

    MAUDE report 8403796 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K121589, K121624, K953385. One submission often covers many models, so check the product and lot details in each record.

  • Z-1220-2017 · Jan 10, 2017 · Terminated
    1.5mm System, Cranio-maxillofacial Bone Screws 1.5 x 4mm HT SD X-DR Screw, Bone Screw
  • Z-0136-2016 · Aug 6, 2015 · Terminated
    Neuro Combo Set Case The cases hold surgical instrumentation in place during handling and storage.
  • Z-0137-2016 · Aug 6, 2015 · Terminated
    Thinflap System Case The cases hold surgical instrumentation in place during handling and storage.
  • Z-0836-2012 · Nov 8, 2010 · Terminated
    Package of center-drive bone screws labeled in part: "***REF: 01-7204***1.5MM" SYSTEM CENTER-DRIVE SCREW, 5/ PKG***1.5 X4MM TITANIUM***CAUTION: FEDERAL LAW RESTRICTS THIS DEVICE T
  • Z-0835-2012 · Nov 8, 2010 · Terminated
    Package of cross-drive bone screws labeled in part: "***REF #95-1504***"1.5MM" SYSTEM HIGH TORQUE (HT) CROSS-DRIVE SCREW, 5/ PK***1.5 X4MM TITANIUM***CAUTION: FEDERAL LAW RESTRICTS
  • Z-2385-2011 · Jul 28, 2010 · Terminated
    ***BIOMET MICROFIXATION BIOMET MICROFIXATION 1520 TRADEPORT DRIVE JACKSONVILLE, FL 32218 USA www.biometmicrofixation.com***6 HOLE REGULAR DOUBLE Y PLATE***"1.5MM SYSTEM PLATE DOUBL
  • Z-2873-2011 · May 17, 2010 · Terminated
    "***REF: 91-6704***THINFLAP SYSTEM CROSS-DRIVE, SELF-DRILLING SCREW 1.5X4MM (.059X.159") (WXL)***TITANIUM***NON-STERILE PRODUCT***BIOMET MICROFIXATION 1520 TRADEPORT DRIVE JACKSON
  • Z-1286-2012 · Apr 26, 2010 · Terminated
    Product is labeled in part: "***REF: 01-7036, LOT 999999, "1.5MM" SYSTEM PLATE L-SHAPE, 3 X 3 HOLE, 100 DEGREE, QTY 00001, CE 0086, 2010-04 *** NON-STERILE PRODUCT ***, LEFT, X-L
  • Z-2206-2010 · Mar 17, 2010 · Terminated
    BIOMET MICROFIXATION "1.5MM" SYSTEM HIGH TORQUE (HT) CROSS-DRIVE SCREW, QTY 1, 1.5 X 4MM TITANIUM. REF 91-1504 1 COUNT and REF 95-1504 - 5 PACK. BIOMET MICROFIXATION 1520 TRADEPO
  • Z-1151-2010 · Oct 6, 2009 · Terminated
    BIOMET MICROFIXATION, "1.5MM" SYSTEM BONE SCREW LP, SELF DRILL, X-DRIVE, SGL.LEAD AUGER POINT, 1.5 X 3.5MM, TITANIUM, NON STERILE PRODUCT. Model 01-7293 and 99-7293-01. BIOMET MI
  • Z-1943-2010 · Oct 5, 2009 · Terminated
    BIOMET MICROFIXATION REF: 91-6103 "1.5MM" SYSTEM HIGH TORQUE (HT), SD, X-DR, SCREW 1.5MM X 3.5MM (WXL) TITANIUM LOT 829760, ***NON STERILE PRODUCT***. Bone screws used along with

Other Plate, cranioplasty, preformed, alterable devices

All Plate, cranioplasty, preformed, alterable devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page