TMJ SYSTEM 99-6581Recalls & reported problems
Biomet Microfixation, Inc · 2.0X11MM FOSSA CROSS-DRIVE SCREW · Class 2 · Implant
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00841036057466), received between Mar 27, 2019 and Oct 6, 2020 — classified as 6 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Device Dislodged or Dislocated1
- Fracture1
- Migration1
- Patient-Device Incompatibility1
Patient problems
- No Information2
- Pain2
- Erythema1
- Extraskeletal ossification1
- Foreign Body In Patient1
- Headache1
- Inadequate Pain Relief1
- Itching Sensation1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryOct 6, 2020Patient-Device Incompatibility; Patient-Device Incompatibility
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Erythema; Itching Sensation; Reaction; Unspecified Infection; Urticaria
MAUDE report 10637467 ↗InjuryJul 13, 2020Migration; Migration
IT WAS REPORTED THAT THE PATIENT IS EXPERIENCING PAIN FOLLOWING IMPLANTATION OF BILATERAL TEMPOROMANDIBULAR JOINT IMPLANTS TWO (2) YEARS AGO. THE PATIENT REPORTS THAT THE IMPLANTS ARE SITTING INCORRECTLY IN THE CONDYLES OF THE PATIENT¿S FACE, ARE SITTING TOO FAR BACK, AND ARE PRESSING ON THE EAR CANAL. THE PATIENT IS RECEIVING BOTOX FOR PAIN MANAGEMENT. THERE IS NO REVISION PLANNED AT THIS TIME. NO ADDITIONAL PATIENT CONSEQUENCES HAVE BEEN REPORTED.
Patient problems: Pain
MAUDE report 10267618 ↗InjuryFeb 6, 2020Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THE PATIENT UNDERWENT A REVISION SURGERY DUE TO HETEROTOPIC BONE GROWTH AND DISLOCATION INVOLVING BILATERAL TEMPOROMANDIBULAR JOINT PROSTHESES. THE PATIENT WAS RECEIVED STOCK IMPLANTS OVER A DECADE AGO, AND CURRENTLY REPORTS LIMITED RANGE OF MOTION, HEADACHES, PAIN AND SWELLING. FIFTEEN MONTHS AGO, THE PATIENT REPORTED HETEROTOPIC OSSIFICATION IN THE JOINT AND IMPLANT DISLOCATION ON THE RIGHT SIDE. THIRTEEN MONTHS AGO, THE PATIENT REPORTED A REVISION SURGERY IN WHICH THE EXISTING IMPLANTS WERE RE-POSITIONED. TRIGGER POINT INJECTIONS AND NERVE BLOCKS HAVE BEEN INADEQUATE REGARDING PAIN MANAGEMENT. NO ADDITIONAL PATIENT CONSEQUENCES WERE REPORTED.
Patient problems: Extraskeletal ossification; Headache; Inadequate Pain Relief; Limited Mobility Of The Implanted Joint; Pain; Swelling
MAUDE report 9677239 ↗InjuryJan 9, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THE PATIENT UNDERWENT A REVISION OF TEMPOROMANDIBULAR JOINT IMPLANTS ON THE RIGHT SIDE DUE TO AN UNKNOWN REASON. STOCK MANDIBLE AND FOSSA IMPLANTS WERE REMOVED AND REPLACED WITH NEW STOCK IMPLANTS. NO ADDITIONAL PATIENT CONSEQUENCES WERE REPORTED.
Patient problems: No Information
MAUDE report 9569618 ↗InjuryApr 1, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION.
Patient problems: No Information
MAUDE report 8470524 ↗InjuryMar 27, 2019Fracture; Fracture
THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION.
Patient problems: Foreign Body In Patient
MAUDE report 8455669 ↗
Other Plate, Bone devices
- MatrixNEURO 04.503.104.01Synthes GmbH · PLATE, BONE252 reports
- RapidSorb 806.004.02SSynthes GmbH · PLATE, BONE146 reports
- TruMatch SD980.001Materialise NV · Plate, Bone1 recall21 reports
- Matrix 04.511.225.01Synthes GmbH · PLATE, BONE62 reports
- NA 400.834Synthes GmbH · PLATE, BONE58 reports
- TruMatch SD980.016Materialise NV · Plate, Bone55 reports
- ProPlan CMF SD900.101Materialise NV · Plate, Bone1 recall1 report
- TruMatch SD980.013Materialise NV · Plate, Bone1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.