Mammotome revolve MST1012Recalls & reported problems
Devicor Medical Products, Inc. · Stereotactic Probe - CE · Class 2
All models of Mammotome revolve (12)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00841911100751), received between Sep 29, 2020 and Sep 29, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
1 other recall cover devices cleared under the same FDA submission (K152989); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 29, 2020Material Fragmentation; Material Fragmentation
IT WAS REPORTED VIA MEDWATCH VOLUNTARY EVENT REPORT THAT DURING A STEREOTACTIC LEFT BREAST BIOPSY PROCEDURE, A 12 CM, 10 GAUGE MAMMOTOME REVOLVE NEEDLE WAS INADVERTENTLY LOADED IN MAMMOTOME INSTEAD OF A 9 CM, 10 GAUGE NEEDLE. BIOPSY OF LEFT BREAST LESION WAS PERFORMED. POST BIOPSY IMAGES SHOWED A 4 MM V SHAPED RETAINED METALLIC FRAGMENT IN LEFT BREAST. INSPECTION OF THE NEEDLE SHOWED A DAMAGED CANNULA AT THE TIP. PATIENT WAS IMMEDIATELY REFERRED TO BREAST CLINIC AND SEEN BY BREAST SURGEON. PATIENT SCHEDULED FOR ELECTIVE SURGERY FOR REMOVAL OF BREAST LESION/CALCIFICATIONS AND RETAINED METALLIC FRAGMENT/FOREIGN BODY. THE ORIGINAL PACKAGING FOR THE PROBE IN QUESTION WAS NOT KEPT, NOR WAS THE PROBE. DEVICE WAS TRACED BACK TO (B)(6) HOSPITAL-(B)(6)(1383998) BASED OFF THE LOT NUMBER.
Patient problems: Foreign Body In Patient
MAUDE report 10601577 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K152989. One submission often covers many models, so check the product and lot details in each record.
- Z-1512-2017 · Feb 28, 2017 · TerminatedMammotome Revolve Dual Vacuum Assist Biopsy System The device is used to sample breast tissue that has been identified as suspicious under imaging guidance
Other Instrument, Biopsy devices
- MAX-CORE MC1616Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall4,258 reports
- ENCOR® ECP017GSenorx, Inc. · INSTRUMENT, BIOPSY1 recall4,186 reports
- MAX-CORE MC1820Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall2,404 reports
- MAX-CORE MC1816Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall1 death848 reports
- MAX-CORE MC1410Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall399 reports
- MAX-CORE MC1610Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall394 reports
- ENCOR® ECP0110GVSenorx, Inc. · INSTRUMENT, BIOPSY392 reports
- ENCOR® ECP0110GSenorx, Inc. · INSTRUMENT, BIOPSY390 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page