Stent FREDX4013-PMARecalls & reported problems

Microvention, Inc. · FRED-X 27 · Class 3 · Implant

All models of Stent (63)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
3
Deaths reported
1
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00842429114346), received between Jan 6, 2025 and Feb 3, 2026 — classified as 1 death, 2 injuries.

The most frequently reported specific device problem is “Activation Failure” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Sep 5, 2025Open, Classified

    Flow diverter may have a manufacturing issue related to the tantalum length and/or tantalum attachment pattern, which may lead the device to be incompletely open or not properly apposed to the vessel wall, which may necessitate device recapture and withdrawal of the delivery system and microcatheter together. Insufficient apposition could lead to long-term health consequences.

    Z-0108-2026 · Root cause: Device Design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Activation Failure1
  • Difficult or Delayed Positioning1
  • Unintended Movement1

Patient problems

  • Obstruction/Occlusion2
  • Muscle Weakness/Atrophy1
  • Numbness1
  • Stenosis1
  • Thrombosis/Thrombus1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 3, 2026Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION RECEIVED PROVIDED THE DEVICE MODEL & LOT NUMBER AND INDICATED: ORIGINAL SURGICAL DATE / STUDY PROCEDURE WAS ON (B)(6) 2024. CORELAB REPORTED THE 40% IN-STENT STENOSIS AT THE 6-MONTH FU IMAGING AND THE CLINICAL SITE REPORTED 90% TARGET ANEURYSM OCCLUSION AT THE 6-MONTH FU IMAGING ALL PERFORMED ON (B)(6) 2024. THE CLINICAL SITE REPORTED 20% TARGET ANEURYSM OCCLUSION AT THE 1-YR FU IMAGING PERFORMED ON (B)(6) 2025. RECANALIZATION HAS NOT BEEN CONFIRMED. NO TREATMENT WAS REQUIRED FOR THE 40% IN-STENT STENOSIS. NO TREATMENT WAS ADMINISTERED FOR AE IN-STENT STENOSIS/INTIMAL HYPERPLASIA OR VITREOUS FLOATERS OF BOTH EYES. TO DATE, NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Obstruction/Occlusion; Stenosis

    MAUDE report 24254521 ↗
  • DeathOct 15, 2025Difficult or Delayed Positioning; Unintended Movement; Activation Failure; Difficult or Delayed Positioning; Unintended Movement; Activation Failure

    NO FURTHER INCIDENT INFORMATION WAS RECEIVED, HOWEVER REVIEW OF RECEIVED IMAGES IS COMPLETED. PLEASE SEE H6 AND H11.

    Patient problems: Obstruction/Occlusion; Thrombosis/Thrombus

    MAUDE report 23287227 ↗
  • InjuryJan 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED THROUGH THE FRED X PAS CLINICAL STUDY, THE SUBJECT REPORTED TO THE EMERGENCY DEPARTMENT WITH COMPLAINT OF WORSENING LEFT UPPER EXTREMITY WEAKNESS AND NUMBNESS. IMAGING WAS PERFORMED THAT WAS NEGATIVE FOR STROKE AND POSITIVE FOR MICROEMBOLIC SIGNAL (MES). MES WAS INCIDENTAL FINDING AND TOO SMALL TO CAUSE THE INDICATED SYMPTOMS. THE SUBJECT WAS RE-STARTED ON DAPT. THE SUBJECT WAS DISCHARGED THE NEXT DAY. THE EVENT WAS ASSESSED AS POSSIBLY RELATED TO THE FLOW DIVERTER STENT DEVICE, WHICH WAS ORIGINALLY IMPLANTED ON (B)(6) 2023. THE ADVERSE EVENT IS ONGOING AND NO FURTHER UPDATES AVAILABLE AT THIS TIME.

    Patient problems: Muscle Weakness/Atrophy; Numbness

    MAUDE report 21087886 ↗