The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00842429117415), received between May 23, 2025 and Dec 18, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Entrapment of Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Entrapment of Device1
  • Fracture1
  • Material Fragmentation1
  • Material Protrusion/Extrusion1

Patient problems

  • Foreign Body In Patient2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 18, 2025Entrapment of Device; Fracture; Entrapment of Device; Fracture

    IT WAS REPORTED THAT DURING A LEFT SIDE MMA EMBOLIZATION WITH LIQUID EMBOLIC, A HEADWAY DUO MICROCATHETER BECAME ENTRAPPED IN LIQUID EMBOLIC. THE PHYSICIAN LEFT A PORTION OF THE CATHETER IN THE EMBOLIC CAST AND REMOVED THE OTHER PORTION. THE PATIENT IS REPORTED TO BE DOING WELL AND IS STABLE.

    Patient problems: Foreign Body In Patient

    MAUDE report 23835946 ↗
  • InjurySep 4, 2025Material Fragmentation; Material Fragmentation

    AS REPORTED: OPERATOR BROKE CATHETER IN MMA BY LEAVING IT IN TOO LONG WITH THE LIQUID EMBOLIC. THE CATHETER WAS LEFT TOO LONG IN THE LIQUID EMBOLIC AND BECAME STUCK, SO WHEN THEY REMOVED IT THE CATHETER TIP BROKE OFF FORCEFULLY AND SOME WAS RETAINED IN THE LIQUID EMBOLIC. CASE WAS COMPLETED. PATIENT IS FINE.

    Patient problems: Foreign Body In Patient

    MAUDE report 22974260 ↗
  • MalfunctionMay 23, 2025Material Protrusion/Extrusion; Material Protrusion/Extrusion

    IT WAS REPORTED THAT THE MICROCATHETER HUB WAS FOUND TO BE DAMAGED DURING PREPARATION. WHEN THE DEVICE WAS RECEIVED FOR EVALUATION, THE LUMEN WAS FOUND TO HAVE NOT BEEN FULLY FLARED AT THE HUB JOINT, WITH AN EXPOSED BRAID AND DELAMINATED PTFE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22080860 ↗