WEB 17 SL 6x2 W5-6-2-MVI-3Recalls & reported problems
Microvention, Inc. · WEB Aneurysm Embolization System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 20
- Deaths reported
- 1
- Injuries reported
- 11
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 20 adverse event reports that list this exact device (DI 00842429117996), received between Jun 9, 2023 and Jun 26, 2026 — classified as 1 death, 11 injuries, 8 malfunctions.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (8 reports).
1 other recall cover devices cleared under the same FDA submission (P170032); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated8
- Difficult or Delayed Separation7
- Adverse Event Without Identified Device or Use Problem2
- Separation Failure2
- Unintended Movement2
- Migration1
Patient problems
- No Clinical Signs, Symptoms or Conditions14
- Aneurysm1
- Aneurysm expansion1
- Insufficient Information1
- Ischemia Stroke1
- Stroke/CVA1
- Vasoconstriction1
Recent adverse event reports
The 20 most recent of 20 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 26, 2026Device Dislodged or Dislocated
IT WAS REPORTED THROUGH THE CLINICAL STUDY CAR THAT A WEB WAS USED FOR EMBOLIZATION OF A BASILAR TIP ANEURYSM. AN INITIAL 5 MM × 2 MM WEB SL DEVICE WAS DEPLOYED; HOWEVER, DUE TO INADEQUATE LATERAL COMPRESSION AND CONCERN FOR RECURRENCE, THE DEVICE WAS RESHEATHED AND EXCHANGED FOR A 6 MM × 2 MM WEB SL DEVICE. IT WAS REPORTED THAT FOLLOW-UP ANGIOGRAPHY DEMONSTRATED COMPLETE ANEURYSM OCCLUSION WITH MILD ENCROACHMENT (APPROXIMATELY 50%) INTO THE PARENT ARTERY AND IMPROVED DEVICE COMPRESSION. THE DEVICE WAS DETACHED WITH STABLE POSITIONING CONFIRMED ON POST-DETACHMENT IMAGING. IT WAS REPORTED THAT AT THE 7-DAY FOLLOW-UP, THE PATIENT EXHIBITED NO NEUROLOGICAL DEFICITS. THE PATIENT WAS DISCHARGED ON (B)(6) 2025 WITH A MODIFIED RANKIN SCALE SCORE OF 0. AT SIX-MONTH FOLLOW-UP ON (B)(6) 2026, MAGNETIC RESONANCE ANGIOGRAPHY DEMONSTRATED COMPLETE ANEURYSM OCCLUSION WITH PRESERVED PARENT ARTERY PATENCY AND PERSISTENT 50% STENOSIS, WITH NO EVIDENCE OF RECURRENCE, HEMORRHAGE, STENT STENOSIS, OR DEVICE MIGRATION. THE PATIENT REMAINED CLINICALLY STABLE WITH A MODIFIED RANKIN SCALE SCORE OF 0.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25643416 ↗InjuryFeb 3, 2026Adverse Event Without Identified Device or Use Problem
AS REPORTED THROUGH THE WEB PAS CLINICAL STUDY: RECURRENT BASILAR APEX ANEURYSM. ANGIOGRAM DEMONSTRATED RECURRENCE OF BASILAR APEX ANEURYSM. THERE IS A PLANNED RETREATMENT IN A FEW WEEKS, PLAN WILL BE FOR BALLOON ASSISTED COILING. PATIENT IS ALIVE AND WAITING FOR RETREATMENT. THE EVENT WAS ASSESSED TO HAVE A CAUSAL RELATION TO THE STUDY DEVICE, AND A POSSIBLE RELATION TO THE INDEX PROCEDURE A STUDY DISEASE. NO TECHNICAL EVENTS OR ADVERSE EVENTS WERE REPORTED FOLLOWING THE INDEX PROCEDURE.
Patient problems: Aneurysm expansion
MAUDE report 24254708 ↗InjuryJan 9, 2026Device Dislodged or Dislocated
IT WAS REPORTED THROUGH THE WEB PAS CLINICAL STUDY: THE FOLLOWING EVENT WAS POSSIBLY DEVICE RELATED: PARAPHRASING FROM THE EMR: DURING DEVICE DEPLOYMENT ¿ EACH TIME THEY TRIED TO DEPLOY THE WEB IT APPEARED TO OCCLUDE THE M2 BRANCHES OF THE RIGHT MCA SO IT WAS RECAPTURED AND REMOVED. THEY SWITCHED MICROCATHETERS. DURING THE NEXT DEPLOYMENT, WEB WAS SLIGHTLY TILTED SO THEY PULLED IT BACK A BIT TO EVEN IT OUT. STILL THERE APPEARED TO BE SOME DEVICE ENCROACHMENT IN THE SAME SPOT AS BEFORE (APPROX. 50%) BUT IMAGING SHOWED NO FLOW LIMITATION OR THROMBUS FORMATION. THE PATIENT IS DOING WELL IN FOLLOW UP.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24030679 ↗DeathNov 10, 2025Difficult or Delayed Separation; Difficult or Delayed Separation
AS REPORTED TO MICROVENTION: "THERE WAS A DETACHMENT ISSUE WITH WEB. THERE WAS A PATIENT FATALITY." THE PATIENT REPORTEDLY PASSED AWAY; THE CAUSE OF DEATH AND ANY CO-MORBIDITIES REMAIN UNKNOWN. THE PHYSICIAN HAS DECLINED TO PROVIDE ADDITIONAL DETAILS BEYOND THE INITIAL INFORMATION SHARED. THE MICROVENTION REPRESENTATIVE FORMALLY ASSIGNED TO THIS ACCOUNT WAS PRESENT DURING THE PROCEDURE BUT REPORTEDLY WAS NOT AWARE OF ANY PRODUCT-RELATED CONCERNS OR ADVERSE EVENT UPON COMPLETION OF THE PROCEDURE.
Patient problems: Insufficient Information
MAUDE report 23518983 ↗InjuryOct 27, 2025Migration; Migration
IT WAS REPORTED THAT THE DOCTOR WAS TREATING AN ACOMM ANEURYSM. THE AVERAGE WIDTH MEASUREMENT WAS 5.25 AND THE SHORTEST HEIGHT WAS 3.1. BASED ON THESE MEASUREMENTS HE CHOSE A 6X2 INSTEAD OF THE 7X2 BECAUSE WE FELT THE 7X2 WOULD ENCROACH ON THE A2 BRANCHES. HE USED A VIA 17 AND SUCCESSFULLY PLACED THE 6X2 WEB WITH SOME STAGNATION IN THE ANEURYSM. ABOUT 6 HOURS AFTER THE PROCEDURE WAS COMPLETE THE PATIENT STARTED SHOWING SIGNS OF A STROKE. THE PHYSICIAN TOOK THE PATIENT BACK TO THE ANGIO SUITE AND SAW THE WEB MIGRATED TO THE DISTAL A2 BRANCH. THE PHYSICIAN TRIED MULTIPLE TIMES TO SNARE THE DISLODGED WEB BUT WAS UNSUCCESSFUL. THE PATIENT HAD LEFT SIDE HEMIPARESIS. THE PATIENT WENT BACK TO THE ICU. ADDITIONAL INFO RECEIVED STATED THAT NO INTERVENTION WAS PERFORMED TO DATE. INTERVENTION WAS PLANNED FOR STENT/COILING TO TREAT THE PATIENT AT SOME POINT. IT WAS LATER REPORTED THAT THE PATIENT IS STILL IN THE HOSPITAL ON THE FLOOR AND NOT ICU ANYMORE. THE PATIENT'S MODIFIED RANKIN SCORE IS 4. THE PATIENT IS STILL EXPERIENCING LEFT HEMIPARESIS, AND IS BED BOUND. THE PATIENT HAD A PEG TUBE PLACED.
Patient problems: Stroke/CVA
MAUDE report 23399067 ↗MalfunctionOct 23, 2025Unintended Movement; Unintended Movement
IT WAS REPORTED THAT UPON DETACHMENT, THE DEVICE ROTATED 90 DEGREES ON ITS SIDE. NO INTERVENTION WAS PERFORMED. THE PROCEDURE WAS COMPLETED. THERE WAS NO PATIENT INJURY. IT WAS REPORTED THAT THE PATIENT OUTCOME WAS STABLE AND THE PATIENT WAS DISCHARGED THE FOLLOWING DAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23375926 ↗InjuryOct 23, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT THE PATIENT CAME IN ORIGINALLY WITH A SUBARACHNOID HEMORRHAGE FROM A RUPTURED SIDEWALL ANEURYSM. THE FIRST WEB EMBOLIZATION DEVICE WAS DEPLOYED BUT REMOVED FOR UNSPECIFIED REASON. A SECOND SMALLER SIZE WEB DEVICE WAS THEN USED AND DEPLOYED BUT WOULDN'T DETACH WHEN ATTEMPTED; HOWEVER, THE DEVICE DETACHED DURING PUSH AND PULL MANEUVERING. FOLLOW-UP IMAGING 10-14 DAYS POST PROCEDURE SHOWED THE WEB HAD PARTIALLY MIGRATED INTO THE MCA AND THE PATIENT EXPERIENCED VASOSPASM. NO MITIGATION WAS DONE AND THE WEB WAS LEFT PARTIALLY PROTRUDING INTO THE MCA AND THE PHYSICIAN DID NOT ATTEMPT TO SNARE OUT THE DEVICE AS CLOT HAD ALREADY FORMED AND FOR FEAR OF EMBOLI BREAK OFF. VESSEL ANATOMY WAS POSSIBLY A FACTOR. THE WEB REMAINS IMPLANTED IN THE PATIENT. CURRENT PATIENT STATUS WAS NOT PROVIDED.
Patient problems: Vasoconstriction
MAUDE report 23375398 ↗InjuryJul 2, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
AS REPORTED THROUGH A WEB PAS CLINICAL STUDY, THE PATIENT WAS BEING TREATED FOR AN UNRUPTURED RIGHT MCA BIFURCATION. DURING A THREE-MONTH CHECKUP, A WEB IMPINGEMENT WAS FIRST SEEN ON AN MRI SCAN. THERE WAS A 30% OF REDUCTION IN THE PARENT ARTERY DUE TO THIS WEB IMPINGEMENT. THE EVENT OCCURRED AFTER WEB IMPLANTATION, AND NO ADDITIONAL TREATMENT IS PLANNED. THE PATIENT HAD A SIX-MONTH CHECKUP, AND THE MRS SCORE WAS ZERO.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22391563 ↗InjuryJul 2, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
THE FOLLOWING EVENT WAS REPORTED THROUGH THE WEB PAS CLINICAL TRIAL. IT WAS REPORTED THAT A WEB DEVICE IMPINGED INTO THE PARENT VESSEL. THE ANGLE OF ANEURYSM AS IT COMES OFF PARENT VESSEL RESULTED IN VERY MINOR IMPINGEMENT OF WEB DEVICE INTO PARENT VESSEL. THIS DID NOT LEAD TO INTERVENTION OR INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22390999 ↗MalfunctionJun 27, 2025Separation Failure; Separation Failure
IT WAS REPORTED THAT UPON TAKING THE WEB OUT OF THE PACKAGING AND TUBING, THE BACK END OF THE DEVICE WAS OBSERVED TO HAVE A VERY SLIGHT BEND. THE BACK END OF THE DEVICE WAS TESTED IN THE DETACHER. AFTER OBSERVING THE STEADY GREEN LIGHT ON THE DETACHER, PHYSICIAN PROCEEDED WITH PLACING THE WEB. AFTER ABOUT 5 MINS OF PLACEMENT AND DEPLOYMENT, PHYSICIAN ATTEMPTED TO DETACH THE WEB. HE CONNECTED TO THE DETACHER TO THE BACK END OF THE DEVICE AGAIN AND THE LIGHT WENT RED AND BEEPED. PHYSICIAN TRIED REPETITIVELY TO GET THE DETACHER TO WORK BUT IT NEVER WORKED. A 2ND DETACHER WAS USED, AND IT WOULD NOT WORK. PHYSICIAN RESHEATHED AND REMOVED THE WEB AND PUT ANOTHER WEB IN. AS THE 1ST WEB WAS REMOVED, IT WAS OBSERVED A MORE DRASTIC BEND TO THE BACK END OF THE WEB DEVICE. PREP, DEPLOYMENT AND DETACHMENT WITH THE 2ND WEB WAS VERY EASY GOING WITH NO PROBLEMS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22351443 ↗MalfunctionFeb 7, 2025Difficult or Delayed Separation; Difficult or Delayed Separation
AS REPORTED: STICKY WEB DETACHMENT. WEB 6X2 WAS DEPLOYED INSIDE RMCA ANEURYSM. INTRODUCED TLC TECHNIQUE, PLACED DETACHED ON PUSHER WIRE, SAW GREEN LIGHT, HEARD THREE AUDIBLE BEEPS AND WHEN WE WENT TO GET THE PUSHER WIRE BACK INTO THE MICROCATHETER IT WAS STILL ATTACHED. WE ADVANCED THE VIA 17 TO THE PROXIMAL MARKER OF THE WEB TO KEEP IT IN PLACE AND PULLED ON THE PUSHER WIRE UNTIL WE SAW A COMPLETE DETACHMENT. THE DEVICE WAS EVENTUALLY IMPLANTED. NO INTERVENTIONS OR THROMBOLYTIC THERAPIES PERFORMED. THE WEB REMAINED IN THE ANEURYSM IN GREAT POSITION. NO ADVERSE EVENTS REPORTED AND PATIENT DOING WELL AS PER MD.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21339401 ↗InjuryJan 9, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
AS REPORTED THROUGH A WEB PAS CLINICAL STUDY, THE WEB WAS DETACHED WITH IMPINGEMENT INTO A PARENT VESSEL AT THE END OF THE PROCEDURE. THE TE DESCRIPTION PER SITE IS MINOR PROTRUSION OF THE BASE OF THE DEVICE INTO THE ORIGIN OF THE PERICALLOSAL ARTERY WITHOUT SIGNIFICANT STENOSIS OR DELAY IN TRANSIENT TIME. THE PATIENT CURRENT CONDITION WAS REPORTED THAT AT 30-DAY FOLLOW UP ON (B)(6) 2024, MRS WAS 1 (SAME AS BASELINE).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21121019 ↗MalfunctionNov 21, 2024Difficult or Delayed Separation; Difficult or Delayed Separation
IT WAS REPORTED THAT THE WEB WOULD NOT DETACH. ONCE DELAYED DETACHMENT WAS CONFIRMED, THE PHYSICIAN BROUGHT THE VIA17 UP TO THE PROXIMAL END OF THE WEB TO SUPPORT AND TRIED TO PULL THE DELIVERY WIRE MORE AGGRESSIVELY. THE WEB FULLY RESHEATHED INTO THE CATHETER AND EVENTUALLY DETACHED INSIDE OF THE VIA17. IT DID NOT DETACH DURING THE RESHEATH AND FLOAT INTO THE VESSEL. THE PATIENT WAS NOT HARMED. A 5X3 WEB WAS PLACED AFTERWARDS WITH A NEW VIA17 MICROCATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20742114 ↗MalfunctionOct 4, 2024Separation Failure; Separation Failure
IT WAS REPORTED THAT DURING AN ANEURYSM EMBOLIZATION CASE, A WEB DEVICE DID NOT DETACH. VARIOUS MANEUVERS WERE CARRIED OUT (PULLING THE PUSHER, APPROACHING WITH THE MICRO, TWISTING THE PUSHER) BUT WITHOUT SUCCESS. IT WAS REMOVED AND ANOTHER WEB WAS IMPLANTED SUCCESSFULLY. THERE WAS NO INJURY OR INTERVENTION. THE PATIENT WAS REPORTED TO BE ¿FINE.¿
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20377987 ↗InjuryJul 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED THROUGH THE WEB PAS CLINICAL STUDY: PATIENT EXPERIENCED LEFT HEMISPHERIC ISCHEMIC STROKE 13 DAYS AFTER INDEX PROCEDURE. THE PATIENT WAS HOSPITALIZED FOR FOUR DAYS AND WAS TREATED FOR MINOR STROKE (NIHSS 1) WITH MEDICATION AND OUTPATIENT PHYSICAL THERAPY. IT WAS DETERMINED BY THE CLINICAL STAFF THAT THERE IS A POSSIBLE RELATION BETWEEN THE ADVERSE EVENT AND THE DEVICE AND PROCEDURE.
Patient problems: Ischemia Stroke
MAUDE report 19697338 ↗InjuryJun 12, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED DURING TREATMENT FOR A POSTERIOR COMMUNICATING ARTERY (PCOM) ANEURYSM WITH A WEB SL WAS USED. AFTER THE WEB DETACHMENT A REPEAT CONTRAST INJECTION WAS PERFORMED, WHICH SHOWED SOME MOVEMENT OF THE WEB INSIDE THE ANEURYSM. A DEMAGNIFIED AP AND LATERAL VIEW OF THE INTRACRANIAL CIRCULATION WAS PERFORMED TO ASSESS FOR THROMBOEMBOLI AND TO VIEW THE ORIENTATION OF THE WEB DEVICE INSIDE THE ANEURYSM. THE SIZE OF THE ANEURYSM WAS 5.16 AVG WIDTH AND 3.14 MINIMUM HEIGHT. THE WEB WAS 6X2 AND OVERSIZED. LATERAL COMPRESSION OF 4.98 ON AP VIEW AND 5.24 ON LATERAL VIEW. ENTRY ANGLE OF ANEURYSM WAS 45 DEGREE. THE RUN SHOWED NO THROMBOEMBOLI BUT THE WEB DEVICE DID ROTATED SIGNIFICANTLY INSIDE THE ANEURYSM AFTER DETACHMENT. A MAGNIFIED AP AND LATERAL VIEW OF THE WEB WAS PERFORMED IN ORDER TO ASSESS THE DEGREE OF WEB ROTATION INSIDE THE ANEURYSM. THE RUN SHOWED THAT DURING DETACHMENT THE WEB DEVICE HAD INDEED ROTATED INSIDE THE ANEURYSM MARKEDLY, SO THAT IT WAS NOT PLACED INSIDE THE ANEURYSM SAC AND THERE WAS A SIGNIFICANT ENDOLEAK AROUND IT AND THERE WAS ALSO A SMALL ADJACENT LATERAL PARACLINOID ICA ANEURYSM. BOTH OF THE POSTERIOR COMMUNICATING ARTERY AND LATERAL PARACLINOID ICA ANEUR
Patient problems: Aneurysm
MAUDE report 19516940 ↗MalfunctionNov 6, 2023Difficult or Delayed Separation; Difficult or Delayed Separation
IT WAS REPORTED THAT A WEB DEVICE WAS DEPLOYED INTO AN ANEURYSM WITHOUT DIFFICULTY. IT WAS RESHEATHED AND REDEPLOYED TWO TIMES TO ACHIEVE OPTIMAL PLACEMENT. THREE DETACHMENT ATTEMPTS WERE MADE WITH THE CONTROLLER AND THE DEVICE PARTIALLY DETACHED. THE CATHETER WAS ADVANCED AND USED TO DETACH THE WEB FROM THE PUSHER. THERE WAS NO INTERVENTION. THE PATIENT WAS STABLE AND INTACT POST PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18071050 ↗InjuryOct 23, 2023Unintended Movement; Difficult or Delayed Separation; Unintended Movement; Difficult or Delayed Separation
ADDITIONAL INFORMATION NOTES THE PATIENT IS DOING WELL AND TOLERATED THE PROCEDURE WITHOUT ISSUE . THE WEB WAS IMPLANTED SUCCESSFULLY. THE LOT NUMBER WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17986768 ↗MalfunctionJun 15, 2023Difficult or Delayed Separation; Difficult or Delayed Separation
PLEASE SEE SECTION H10 FOR DEVICE INVESTIGATION RESULTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17140578 ↗InjuryJun 9, 2023Device Dislodged or Dislocated; Difficult or Delayed Separation; Device Dislodged or Dislocated; Difficult or Delayed Separation
AS REPORTED, THE WEB DEVICE WAS USED TO TREAT A 4.9MM X 3.0MM PCOMM ANEURYSM. THE WEB WOULD NOT DETACH AND DURING MANEUVERING, THE PHYSICIAN TRIED SLIGHT REVERSE TRACTION ON THE PUSHER WIRE AND USED THE DETACHMENT CONTROLLER TO DETACH THE WEB. AFTER DETACHMENT, THE PHYSICIAN USED A SCEPTER XC BALLOON CATHETER TO RE-POSITION THE WEB DEVICE; HOWEVER, THE GUIDEWIRE USED WITH THE SCEPTER XC BALLOON PUSHED THE WEB OUT OF THE ANEURYSM. THE PHYSICIAN USED A SNARING DEVICE TO RETRIEVE THE DEVICE OUT OF THE PATIENT AND USED A NEW WEB SL DEVICE TO SUCCESSFULLY COMPLETE THE CASE. OUTCOME WAS GOOD AND PATIENT WAS DISCHARGED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17099511 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P170032. One submission often covers many models, so check the product and lot details in each record.
- Z-0170-2023 · Sep 21, 2022 · Open, ClassifiedWEB Detachment Controller, REF: WDC-2, WDC, MV-WDC2. Component of WEB Aneurysm Embolization System.
Other Intrasaccular Flow Disruption Device devices
- WEB Detachment Controller WDC-2-MVIMicrovention, Inc. · Intrasaccular Flow Disruption Device1 recall0 reports
- WEB W5-4-2-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device1 death23 reports
- WEB W5-5-2-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device20 reports
- WEB W5-4.5-2-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device19 reports
- WEB W5-7-3-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device1 death16 reports
- WEB W5-6-3-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device1 death15 reports
- WEB W5-5-3-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device14 reports
- WEB Aneurysm Embolization System W2-8-3-MVI-3Microvention, Inc. · Intrasaccular Flow Disruption Device14 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page