Hana/ProFx Traction Boot XLarge (pr) 6850-487Recalls & reported problems
Mizuho Orthopedic Systems, Inc. · Left and Right boots · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842430106491), received between May 25, 2018 and May 25, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Component Misassembled” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Component Misassembled1
- Detachment Of Device Component1
- Detachment of Device or Device Component1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 25, 2018Detachment Of Device Component; Detachment of Device or Device Component; Component Misassembled; Detachment Of Device Component; Detachment of Device or Device Component; Component Misassembled
IT WAS REPORTED THE CUSTOMER WAS USING THE HANA TABLE FOR A ANTERIOR HIP REPLACEMENT CASE. WHEN THE RN IN THE ROOM PULLED TRACTION FOR THE SURGEON DURING THE CASE, THE ALLEN SCREW THAT WAS HOLDING THE BASE PLATE TO THE BOOT BROKE APART, AND THE BOOT WAS LEFT SWINGING WITH THE PATIENT'S FOOT STILL ATTACHED IN BOOT. NURSE WENT UNDER THE DRAPES TO SECURE THE PATIENTS FOOT AND IMMEDIATELY CHANGED THE BOOT ON THE PATIENT'S FOOT. WE NOTICED AFTER THE CASE THAT THE BOOT WAS INCORRECTLY MANUFACTURED WITH TWO WASHERS PLACED ON THE BOOT AND NOT ALLOWING THE ALLEN SCREW ENOUGH THREADS TO HOLD THE WEIGHT PLACED UPON IT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7544879 ↗
Other Table, Surgical With Orthopedic Accessories, Ac-Powered devices
- TS 7000 1604788Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall4 reports
- TS 7500 1717023Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall1 report
- TS 7500 1704695Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- TS 7500 1854085Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- TS 7500 1854087Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- ADVANCED CONTROL I-BASE, DC 5803Mizuho Orthopedic Systems, Inc. · Table, Surgical With Orthopedic Accessories, Ac-Powered47 reports
- TRUMPF MEDICAL 1723633Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED43 reports
- TABLE, HANA, 110 V 6875Mizuho Orthopedic Systems, Inc. · Table, Surgical With Orthopedic Accessories, Ac-Powered2 deaths36 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.