Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842430107016), received between Dec 15, 2020 and Dec 15, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Unintended Movement” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Unintended Movement1
Patient problems
- Fall1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 15, 2020Unintended Movement; Unintended Movement
IT WAS REPORTED, DURING SPINAL SURGERY, THE ORTHOPEDIC DOCTOR INSTRUCTED THE ANESTHESIOLOGY TRAINEE TO TILT ACTION. HOWEVER, THE HAND PENDANT DID NOT RESPOND BECAUSE THE 180 DEGREE ROTATION LOCK BLUE HANDLE (HEAD SIDE) WAS UNLOCKED FOR SOME REASON. WHILE THE ANESTHESIOLOGY TRAINEE SUSPECTED A PROBLEM AND WAS OPERATING VARIOUS OPERATIONS, HE PRESSED THE ROTATION SAFETY LOCK SWITCH (LEG SIDE). AT THAT MOMENT, THE 180 DEGREE ROTATION LOCK WAS COMPLETELY UNLOCKED, THE TABLE ROTATED UNDER THE PATIENT'S OWN WEIGHT AND THE PATIENT FELL FROM HEAD TO THE FLOOR.
Patient problems: Fall
MAUDE report 11011169 ↗
Other Table, Surgical With Orthopedic Accessories, Ac-Powered devices
- TS 7000 1604788Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall4 reports
- TS 7500 1717023Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall1 report
- TS 7500 1704695Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- TS 7500 1854085Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- TS 7500 1854087Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- ADVANCED CONTROL I-BASE, DC 5803Mizuho Orthopedic Systems, Inc. · Table, Surgical With Orthopedic Accessories, Ac-Powered47 reports
- TRUMPF MEDICAL 1723633Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED43 reports
- TABLE, HANA, 110 V 6875Mizuho Orthopedic Systems, Inc. · Table, Surgical With Orthopedic Accessories, Ac-Powered2 deaths36 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page