Skip to content

Multifibren® U 10446691Recalls & reported problems

Siemens Healthcare Diagnostics Products GmbH · Quantitative determination of fibrinogen in plasma · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842768017872), received between Apr 4, 2019 and Apr 4, 2019 — classified as 1 malfunction.

The most frequently reported specific device problem is “High Test Results” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • High Test Results1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 4, 2019High Test Results; High Test Results

    THREE DISCORDANT, FALSELY ELEVATED FIBRINOGEN RESULTS WERE OBTAINED ON THREE PATIENT SAMPLES USING MULTIFIBREN U REAGENT ON AN ATELLICA COAG 360 SYSTEM. THE DISCORDANT RESULTS WERE REPORTED TO THE PHYSICIAN(S). TWO OF THE THREE SAMPLES WERE REPEATED USING THE FIB MULTI U LOW METHOD WITH THE SAME MULTIFIBREN U REAGENT ON THE SAME ATELLICA COAG 360 SYSTEM, RESULTING LOWER. THE SAME THREE SAMPLES WERE REPEATED AT ANOTHER LABORATORY ON A SYSMEX CS-5100 SYSTEM USING DADE THROMBIN REAGENT, ALSO RESULTING LOWER. THE CUSTOMER DID NOT INDICATE IF THE REPEAT RESULTS WERE REPORTED TO THE PHYSICIAN(S). THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT, FALSELY ELEVATED FIBRINOGEN RESULTS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8482833 ↗

FDA clearance and classification

Cleared through 510(k) K934326 on Apr 19, 1994 (decision: Substantially Equivalent). Submitted by Behring Diagnostics, Inc. as “Multifibren U”. The FDA review took 228 days. FDA record ↗

The FDA regulates product code KQJ (system, fibrinogen determination) under 21 CFR 864.7340 as a Class II device. 21 CFR 864.7340 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Multifibren® U 10446691

Has the Multifibren® U 10446691 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00842768017872), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Multifibren® U 10446691?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 4, 2019. That report lists device problem “High Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Multifibren® U 10446691?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Multifibren® U 10446691 FDA approved?

It was cleared through 510(k) K934326 on Apr 19, 1994. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Multifibren® U 10446691, and is it still sold?

The FDA's device database lists Siemens Healthcare Diagnostics Products GmbH as the company responsible for it (brand Multifibren® U, model 10446691). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SYSTEM, FIBRINOGEN DETERMINATION devices

All SYSTEM, FIBRINOGEN DETERMINATION devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page