Dimension Vista® V-LYTE® Integrated Multisensor Na+ / K+ / Cl- 10484429Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · V-LYTE Integrated Multisensor · Class 2
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00842768030413), received between Oct 19, 2017 and Sep 3, 2025 — classified as 10 malfunctions.
The most frequently reported specific device problem is “High Test Results” (6 reports).
32 other recalls cover devices cleared under the same FDA submission (K051087); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- High Test Results6
- Low Test Results3
- Incorrect, Inadequate or Imprecise Result or Readings1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- No Known Impact Or Consequence To Patient3
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 3, 2025Low Test Results; Low Test Results
THE CUSTOMER REPORTED TO SIEMENS THEY OBTAINED AN ERRONEOUSLY DEPRESSED SODIUM (NA) RESULT ON ONE (1) PATIENT SAMPLE ON THE DIMENSION VISTA 500 SYSTEM. THE ERRONEOUSLY DEPRESSED RESULT WAS REPORTED TO THE PHYSICIAN AND QUESTIONED. THIS SAMPLE COULD NOT BE REPROCESSED DUE TO QUANTITY NOT SUFFICIENT. A NEW SAMPLE WAS DRAWN AND PROCESSED ON AN ALTERNATE DIMENSION VISTA 500 SYSTEM. A HIGHER RESULT WAS OBTAINED, CONSIDERED CORRECT, AND REPORTED TO THE PHYSICIAN. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ERRONEOUSLY DEPRESSED SODIUM (NA) RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22954560 ↗MalfunctionNov 6, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED TO SIEMENS THAT THEY OBTAINED ERRONEOUS SODIUM (NA) RESULTS ON MULTIPLE PATIENT SAMPLES ON A DIMENSION VISTA 500 SYSTEM, RESULTING IN NEGATIVE ANION GAPS. THE ERRONEOUS RESULTS WERE NOT REPORTED TO THE PHYSICIAN(S). THE SAME SAMPLES WERE REPROCESSED ON AN ALTERNATE DIMENSION VISTA 500 SYSTEM. THE REPROCESSED RESULTS FROM AN ALTERNATE DIMENSION VISTA 500 SYSTEM MATCHED THE PATIENT¿S CLINICAL PICTURE AND WERE REPORTED AS THE CORRECT RESULTS TO THE PHYSICIAN(S), RESULTING IN POSITIVE ANION GAPS. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ERRONEOUS SODIUM (NA) RESULTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20619991 ↗MalfunctionOct 10, 2024High Test Results; High Test Results
THE CUSTOMER REPORTED TO SIEMENS THAT THEY OBTAINED DISCORDANT ELEVATED POTASSIUM (K) RESULTS ON PATIENT SAMPLES ON A DIMENSION VISTA 1500 INTELLIGENT LAB SYSTEM. THE PATIENT RESULTS WERE REPORTED TO THE PHYSICIAN AND WERE QUESTIONED. IT IS UNKNOWN IF THE SAMPLES WERE REPEATED AND CORRECTED REPORTS WERE ISSUED. THE CUSTOMER DID NOT PROVIDE THE PATIENT DATA. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ELEVATED POTASSIUM (K) RESULTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20415983 ↗MalfunctionOct 10, 2024High Test Results; High Test Results
THE CUSTOMER REPORTED TO SIEMENS THEY OBTAINED DISCORDANT ELEVATED SODIUM (NA) RESULTS ON PATIENT SAMPLES ON A DIMENSION VISTA 1500 INTELLIGENT LAB SYSTEM. THE PATIENT RESULTS WERE REPORTED TO THE PHYSICIAN AND WERE QUESTIONED. IT IS UNKNOWN IF THE SAMPLES WERE REPEATED AND CORRECTED REPORTS WERE ISSUED. THE CUSTOMER DID NOT PROVIDE THE PATIENT DATA. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ELEVATED SODIUM (NA) RESULTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20415962 ↗MalfunctionOct 20, 2023High Test Results; High Test Results
A DISCORDANT FALSELY ELEVATED SODIUM (NA) PATIENT SAMPLE RESULT WAS OBTAINED ON A DIMENSION VISTA 1500 SYSTEM. THE FALSELY ELEVATED RESULT WAS NOT REPORTED TO THE PHYSICIAN. THE SAME SAMPLE WAS REPROCESSED ON AN ALTERNATE DIMENSION VISTA 1500 SYSTEM AND ON THE ORIGINAL DIMENSION VISTA 1500 SYSTEM. LOWER RESULTS, CONSIDERED CORRECT, WERE OBTAINED. THE LOWER REPROCESSED RESULT FROM THE ALTERNATE DIMENSION VISTA 1500 SYSTEM WAS REPORTED AS THE CORRECT RESULT TO THE PHYSICIAN. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE FALSELY ELEVATED SODIUM (NA) RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17974531 ↗MalfunctionSep 28, 2018Low Test Results; Low Test Results
A DISCORDANT DEPRESSED POTASSIUM (K) RESULT WAS OBTAINED ON A PATIENT SERUM SAMPLE ON THE DIMENSION VISTA 500 SYSTEM. THIS RESULT WAS REPORTED TO THE PHYSICIAN WHO QUESTIONED THE RESULT. A NEW SAMPLE WAS DRAWN LATER THE SAME DAY AND A HIGHER RESULT WAS OBTAINED IN AGREEMENT WITH EARLIER RESULTS AT AN ALTERNATE FACILITY. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT DEPRESSED POTASSIUM RESULT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7920014 ↗MalfunctionSep 28, 2018Low Test Results; Low Test Results
A DISCORDANT DEPRESSED POTASSIUM (K) RESULT WAS OBTAINED ON A PATIENT SERUM SAMPLE ON THE DIMENSION VISTA 500 SYSTEM. THIS RESULT WAS REPORTED TO THE PHYSICIAN WHO QUESTIONED THE RESULT. A REDRAW SAMPLE WAS DRAWN LATER THE SAME DAY AND A HIGHER RESULT WAS OBTAINED IN AGREEMENT WITH EARLIER RESULTS AT AN ALTERNATE FACILITY. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT DEPRESSED POTASSIUM RESULT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7920012 ↗MalfunctionMar 14, 2018High Test Results; High Test Results
DISCORDANT, IMPRECISE POTASSIUM (K) RESULTS WERE OBTAINED ON A PATIENT SAMPLE ON THE DIMENSION VISTA 500 INSTRUMENT. THERE ARE NO REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT, IMPRECISE POTASSIUM RESULTS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7339706 ↗MalfunctionMar 14, 2018High Test Results; High Test Results
A DISCORDANT, IMPRECISE POTASSIUM (K) RESULT WAS OBTAINED ON A PATIENT SAMPLE ON THE DIMENSION VISTA 500 INSTRUMENT. THE RESULT WAS REPORTED. THERE ARE NO REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT, IMPRECISE POTASSIUM RESULT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7339703 ↗MalfunctionOct 19, 2017High Test Results; High Test Results
A DISCORDANT HIGH POTASSIUM (K) RESULT WAS OBTAINED ON A PLASMA SAMPLE ON THE DIMENSION VISTA 1500 SYSTEM. THE PATIENT PLASMA RESULT WAS NOT REPORTED TO THE PHYSICIAN. A SERUM SAMPLE FROM THE SAME DRAW WAS RUN ON THE SAME DAY ON THE SAME DIMENSION VISTA INSTRUMENT AND A LOWER RESULT WAS OBTAINED AND IT WAS REPORTED. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT HIGH PLASMA POTASSIUM (K) RESULT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6963378 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K051087. One submission often covers many models, so check the product and lot details in each record.
- Z-0331-2022 · Oct 15, 2021 · TerminatedDimension Vista 500- In-vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral intensities to determi
- Z-0330-2022 · Oct 15, 2021 · TerminatedDimension Vista 1500 In-vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral intensities to determi
- Z-1014-2019 · Dec 12, 2018 · TerminatedDimension Vista 500, Analyzer, chemistry Model no. 10284473
- Z-0616-2019 · Oct 16, 2018 · TerminatedDimension Vista 500, model no. 10284473 an in vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral
- Z-1703-2017 · Mar 3, 2017 · TerminatedDimension Vista 500 Intelligent Lab System and Dimension Vista 1500 Intelligent Lab System, analyzer, chemistry (photometric, discrete), for clinical use Product Usage: The Siemen
- Z-1886-2016 · Mar 24, 2016 · TerminatedDimension Vista 1500 Intelligent Lab System running on software versions V.3.6.1 SP1 or V.3.6.2, Device listing # D011374, All serial numbers and lots are affected. The Dimension
- Z-1885-2016 · Mar 24, 2016 · TerminatedDimension Vista 500 Intelligent Lab System running on software versions V.3.6.1 SP1 or V.3.6.2, Device listing # D011374, All serial numbers and lots are affected. The Dimension V
- Z-1622-2016 · Feb 16, 2016 · TerminatedDimension Vista Blood Urea Nitrogen (BUN) Flex reagent cartridge The BUN method is an in vitro diagnostic test for the quantitative measurement of urea nitrogen (an end product of
- Z-2054-2015 · May 21, 2015 · TerminatedSiemens Healthcare Diagnostics Dimension Vista Systems, used with the Dimension Vista Intelligent Lab System software version 3.6.1. In vitro diagnostic analyzer.
- Z-0838-2015 · Nov 5, 2014 · TerminatedDimension Vista 500 Intelligent Lab System or Dimension Vista 1500 Intelligent Lab System: An in vitro diagnostic device intended to duplicate manual analytical procedures such a
- Z-0024-2015 · Aug 28, 2014 · TerminatedDimension Vista Mass CKMB Isoenzyme Calibrator (MMB CAL) an in vitro diagnostic product for the calibration of Creatine Kinase MB Isoenzyme (MMB) method on the Dimension Vista Syst
- Z-1733-2014 · Apr 14, 2014 · TerminatedSiemens Healthcare Diagnostics Vista Air Compressor. Vista AirCompressor replacement part: SMN 10706557 SKIT Air Compressor Assy, used on the Dimension Vista 500 and Dimension V
- Z-0851-2014 · Oct 7, 2013 · TerminatedUser Defined Method Flex Assignment/Siemens Dimension Vista 500 or Dimension Vista 1500 System with software version 3.5.1 or lower User Defined Method Flex Assignment/Siemens Dim
- Z-2088-2013 · Jun 19, 2013 · TerminatedDimension Vista 500 and Dimension Vista 1500 System Aliquot Well Double Dispense with software versions 3.5.1 and 3.6. In vitro diagnostic device intended to duplicate manual an
- Z-0430-2014 · May 20, 2013 · TerminatedDimension Vista(R) 500 and Dimension Vista(R) 1500 - Reloaded Vista Vials - limited to systems using software versions 3.4 and 3.5.1. Diagnostic device intended to determine a var
…and 17 more.
Other ELECTRODE, ION SPECIFIC, POTASSIUM devices
- FlexLab FLXInpeco SA · Electrode, Ion Specific, Potassium8 recalls17 reports
- Aptio Automation AP2Inpeco SA · Electrode, Ion Specific, Potassium5 recalls6 deaths16 reports
- Accelerator a3600 ACPInpeco SA · Electrode, Ion Specific, Potassium5 recalls13 reports
- FlexLab X FXXInpeco SA · Electrode, Ion Specific, Potassium2 recalls2 reports
- EPOC BGEM CREA TEST CARD CT-1006-00-00Epocal Inc · Electrode, Ion Specific, Potassium2 recalls1 death1 report
- cobas b 221 <6> system 3337154001Roche Diagnostics GmbH · ELECTRODE, ION SPECIFIC, POTASSIUM1 recall43 reports
- EPOC READER HR-1002-00-00Epocal Inc · Electrode, Ion Specific, Potassium11 deaths88 reports
- HOST 2, EPOC HH-1009-00-00Epocal Inc · Electrode, Ion Specific, Potassium1 recall1 death7 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.