RD SET 4052Recalls & reported problems
Masimo Corporation · RD SET DBI Adult Soft Reusable Sensor · Class 2
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00843997014298), received between Feb 21, 2020 and Dec 31, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Incorrect Measurement” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect Measurement2
- Low Readings1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 31, 2025Incorrect Measurement; Incorrect Measurement
THE CUSTOMER REPORTED "THE SENSOR STOPPED WORKING WHEN THE PATIENT WAS CONNECTED, BUT THERE WAS NO BREAKAGE ON THE DEVICE. THIS TYPE OF SENSOR HAS A HIGHER IMPEDANCE, RESULTING IN A SATURATION READING APPROXIMATELY 8-10 POINTS LOWER THAN ARTERIAL BLOOD GAS ANALYSIS. THIS HAS BEEN REPORTED SEVERAL TIMES BY MY TEAM. THE PERFUSION SIGNAL IS ABOVE 1, INDICATING A GOOD SIGNAL AND WAVEFORM." "THE CLINICIANS OBSERVED A SIGNIFICANT DISCREPANCY BETWEEN THE BLOOD GAS MEASUREMENT AND THE SPO2 MEASUREMENT." THE SPO2 MEASUREMENT FROM THE SENSOR WAS 99% AND THE ABG SO2 MEASUREMENT WAS 83.7%. THERE WAS NO PATIENT IMPACT OR CONSEQUENCE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23936830 ↗MalfunctionDec 31, 2025Incorrect Measurement; Incorrect Measurement
THE CUSTOMER REPORTED "THE SENSOR STOPPED WORKING WHEN THE PATIENT WAS CONNECTED, BUT THERE WAS NO BREAKAGE ON THE DEVICE. THIS TYPE OF SENSOR HAS A HIGHER IMPEDANCE, RESULTING IN A SATURATION READING APPROXIMATELY 8-10 POINTS LOWER THAN ARTERIAL BLOOD GAS ANALYSIS. THIS HAS BEEN REPORTED SEVERAL TIMES BY MY TEAM. THE PERFUSION SIGNAL IS ABOVE 1, INDICATING A GOOD SIGNAL AND WAVEFORM." "THE CLINICIANS OBSERVED A SIGNIFICANT DISCREPANCY BETWEEN THE BLOOD GAS MEASUREMENT AND THE SPO2 MEASUREMENT." THE SPO2 MEASUREMENT FROM THE SENSOR WAS 99% AND THE ABG SO2 MEASUREMENT WAS 83.7%. THERE WAS NO PATIENT IMPACT OR CONSEQUENCE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23936813 ↗MalfunctionFeb 21, 2020Low Readings; Low Readings
THE CUSTOMER REPORTED THE DEVICE PROVIDED LOW/INCONSISTENT READINGS. THE READING WAS ALSO FLUCTUATING, NOT A STABLE READING. NO PATIENT IMPACT OR CONSEQUENCES WERE REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9742302 ↗
Other Oximeter devices
- Trilogy Trilogy100 Ventilator, InternationalRespironics, Inc. · Oximeter8 deaths2,493 reports
- Trilogy Trilogy 202 Ventilator, United StatesRespironics, Inc. · Oximeter2 deaths1,594 reports
- HAMILTON-G5 159001Hamilton Medical AG · Oximeter18 deaths1,440 reports
- Trilogy Trilogy100 Ventilator, GermanyRespironics, Inc. · Oximeter696 reports
- Model EMV+ Vent, Army, MRI 799-EMVP-04Zoll Medical Corporation · Oximeter1 death605 reports
- Trilogy Evo, O2, Japan JP2100X16BRespironics, Inc. · Oximeter4 recalls5 deaths342 reports
- Model EMV+ Vent, Army, COMMERCIAL 799-EMVP-01-01Zoll Medical Corporation · Oximeter1 death497 reports
- HAMILTON-G5 159002Hamilton Medical AG · Oximeter3 deaths451 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.