Skip to content

OsteoMed 214-0080Recalls & reported problems

Osteomed LLC · Medium 4 Hole BSSO Plate · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00845694003599), received between Dec 27, 2022 and Dec 27, 2022 — classified as 3 injuries.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Patient Device Interaction Problem3

Patient problems

  • Insufficient Information2
  • Discomfort1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 27, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    THE PATIENT WAS IMPLANTED ON (B)(6) 2022 WITH NO ISSUES POST-OP OR DURING CLINICAL FOLLOW UP UNTIL THE PATIENT STARTED REPORTING DISCOMFORT AROUND (B)(6) 2022 (EVENT DATE) AT WHICH TIME IMAGING SUGGESTED THE SCREW ON THE LEFT SIDE PLATE APPEARED OUT OF THE USUAL LOCATION. EXPLORATORY SURGERY WAS PERFORMED ON (B)(6) 2022 AND FOUND LOOSENING OF THE PLATE AND "SLIGHT MOVEMENT OF THE DISTAL STUMP". THE PATIENT WAS THEN REFERRED TO THE (B)(6) FOR EMERGENCY REMOVAL AND REFIXATION WHICH TOOK PLACE ON (B)(6) 2022. THE IMPRESSION WAS THAT THE MANDIBULLARY BONE HAD REABSORBED AROUND THE SCREWS AND GRANULATION TISSUE HAD FORMED AT THE SITE. BACTERIAL CULTURE OF MATERIAL COLLECTED REVEALED IT WAS NEGATIVE. IT WAS REPORTED "THEY WILL BE FORWARDING THE SCREWS REMOVED FROM THE PATIENT'S SECOND SURGERY"- PRESUMABLY, THE DEVICES EXPLANTED DURING THE REVISION ON (B)(6) 2022. IT WAS ALSO REPORTED THE PATIENT MIGHT BE DIAGNOSED WITH METALLOSIS (CLINICAL HYPOTHESIS), AND IT COULD BE RELATED TO PLATES AND SCREWS IMPLANTED. NO FURTHER INFORMATION HAS BEEN PROVIDED. REPORT 25 OF 57 FOR THIS EVENT.

    Patient problems: Discomfort

    MAUDE report 16049457 ↗
  • InjuryDec 27, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THE PATIENT MIGHT BE DIAGNOSED WITH METALLOSIS (CLINICAL HYPOTHESIS), AND IT COULD BE RELATED TO THE IMPLANTED PLATES AND SCREWS. NO FURTHER INFORMATION HAS BEEN PROVIDED. REPORT 2 OF 40 FOR THIS EVENT.

    Patient problems: Insufficient Information

    MAUDE report 16049295 ↗
  • InjuryDec 27, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THE PATIENT MIGHT BE DIAGNOSED WITH METALLOSIS (CLINICAL HYPOTHESIS), AND IT COULD BE RELATED TO THE IMPLANTED PLATES AND SCREWS. NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Insufficient Information

    MAUDE report 16049293 ↗

FDA clearance and classification

The FDA regulates product code DZL (screw, fixation, intraosseous) under 21 CFR 872.4880 as a Class II device. 21 CFR 872.4880 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the OsteoMed 214-0080

Has the OsteoMed 214-0080 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00845694003599), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the OsteoMed 214-0080?

The FDA's MAUDE database lists 3 adverse event reports for this device, received on Dec 27, 2022. In those reports, the most common specific device problem is “Patient Device Interaction Problem” (3); the most common patient problem is “Discomfort” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the OsteoMed 214-0080?

None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the OsteoMed 214-0080 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the OsteoMed 214-0080, and is it still sold?

The FDA's device database lists Osteomed LLC as the company responsible for it (brand OsteoMed, model 214-0080). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SCREW, FIXATION, INTRAOSSEOUS devices

All SCREW, FIXATION, INTRAOSSEOUS devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page