Skip to content

OsteoMed 214-2011Recalls & reported problems

Osteomed LLC · MFx Angulated Locking BSSO Plate, 6 Hole, Short · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00845694026512), received between Nov 16, 2021 and Nov 16, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • Bone Fracture(s)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 16, 2021Fracture; Fracture

    ON 03AUG2020 THE SALES MANAGER REPORTED A PLATE FRACTURE EXPLANT IN (B)(6) WITH (B)(4). ON 05AUG2020 THE QUALITY ANALYST AT (B)(4) (OSTEOMED DISTRIBUTOR) NOTIFIES: "PATIENT (B)(6), VICTIM OF TRAUMA TO THE FACE BY A LARGE ANIMAL, UNDERWENT A SURGICAL PROCEDURE ON (B)(6) 2021, WHERE TEMPORARY STABILIZATION OF THE MANDIBULAR FRACTURE AND SUTURES OF THE WOUNDS ON THE FACE WERE PERFORMED. ON (B)(6) 2021, THE PATIENT UNDERWENT A SURGICAL PROCEDURE TO TREAT A COMPLEX MANDIBULAR FRACTURE ON THE RIGHT SIDE AND MIDDLE THIRD OF THE FACE. AT THE TIME, 01 (ONE) STRAIGHT PLATE BSSO 04 HOLES, 01 (ONE) STRAIGHT PLATE BSSO 06 HOLES AND 01 (ONE) TRAPEZOIDAL PLATE 05 HOLES OF THE 2.0 LOCKED ANGLED SYSTEM OF THE OSTEOMED BRAND WERE USED FOR FIXATION OF THE MANDIBULAR FRACTURE OF TLHE MIDDLE 1/3 OF THE FACE. IT TURNS OUT THAT, AFTER ROUTINE EXAMINATIONS, AN IMAGE COMPATIBLE WITH A 06 HOLE PLATE FRACTURE WAS FOUND IN THE BASILAR REGION OF THE MANDIBLE BODY. NEW SURGICAL INTERVENTION WAS PERFORMED TODAY (B)(6) 2021, WHERE THE TWO STRAIGHT ANGLED BSSO BOARDS BLOCKED "FRON" THE 2.0 SYSTEM WERE REMOVED AND REPLACED BY 01 (ONE) BOARD 2.4 ANGLED BLOCKED WITH 6 HOLES."

    Patient problems: Bone Fracture(s)

    MAUDE report 12819568 ↗

FDA clearance and classification

The FDA regulates product code JEY (plate, bone) under 21 CFR 872.4760 as a Class II device. 21 CFR 872.4760 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the OsteoMed 214-2011

Has the OsteoMed 214-2011 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00845694026512), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the OsteoMed 214-2011?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Nov 16, 2021. That report lists device problem “Fracture” (1); patient problem “Bone Fracture(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the OsteoMed 214-2011?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the OsteoMed 214-2011 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the OsteoMed 214-2011, and is it still sold?

The FDA's device database lists Osteomed LLC as the company responsible for it (brand OsteoMed, model 214-2011). Its record shows it as in commercial distribution.