TORNIER PERFORM™ HUMERAL SYSTEM DWP4426Recalls & reported problems
Tornier, Inc. · Class 2 · Implant
All models of TORNIER PERFORM HUMERAL SYSTEM (68)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00846832084715), received between May 2, 2024 and May 2, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Unspecified Infection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AFTER UNDERGOING REVISION SURGERY, THE PATIENT BECAME INFECTED, LEADING TO THE REMOVAL OF ALL IMPLANTS. THE INFECTION WAS DISCOVERED BY THE SURGEON, LOCALIZED IN THE SHOULDER JOINT. THE SURGERY TO REMOVE THE IMPLANTS OCCURRED SHORTLY AFTERWARD. MICROORGANISMS WERE NOT IDENTIFIED, AND THERE WAS NO PRIOR INFECTION NEAR THE SURGICAL SITE. THE STERILE BARRIER OF THE DEVICE PACKAGE REMAINED INTACT, AND NO RE-STERILIZATION WAS PERFORMED BEFORE SURGERY. NO ENVIRONMENTAL MONITORING ALERTS WERE RECORDED BEFORE THE SURGERY. THE INFECTION WAS REPORTED BY THE SURGEON, WHO THEN PROCEEDED TO REMOVE ALL IMPLANTS AND INSERT A CEMENT SPACER.
Patient problems: Unspecified Infection
MAUDE report 19235112 ↗
Other shoulder prosthesis, reverse configuration devices
- DJO SURGICAL 508-36-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration508 reports
- DJO SURGICAL 508-32-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration433 reports
- DJO SURGICAL 508-32-103Encore Medical, L.P. · shoulder prosthesis, reverse configuration421 reports
- DJO SURGICAL 509-00-036Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall259 reports
- DJO SURGICAL 508-32-104Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall203 reports
- DJO SURGICAL 509-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration233 reports
- DELTA XTEND 130760000Depuy (Ireland) · shoulder prosthesis, reverse configuration223 reports
- DJO SURGICAL 508-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration122 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page