Tornier Simpliciti® Shoulder System 7122876Recalls & reported problems

Tornier, Inc. · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00846832090495), received between Apr 14, 2023 and Aug 28, 2025 — classified as 5 injuries.

The most frequently reported specific device problem is “Difficult to Remove” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Difficult to Remove1
  • Naturally Worn1
  • Unstable1

Patient problems

  • Joint Laxity2
  • Insufficient Information1
  • Muscle/Tendon Damage1
  • Unspecified Infection1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, THE REVISION SURGERY WAS PERFORMED IN WHICH ANATOMIC SHOULDER WAS REVISED TO REVERSE DUE TO SUBSCAPULARIS REPAIR FAILING. NO IMPLANT FAILURE WAS NOTED.

    Patient problems: Muscle/Tendon Damage

    MAUDE report 22913092 ↗
  • InjuryJan 2, 2025Unstable; Unstable

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED UNTIL (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO INSTABILITY, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: SINGLE STAGE REVISION.

    Patient problems: Joint Laxity

    MAUDE report 21055890 ↗
  • InjurySep 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2021 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: SINGLE STAGE REVISION.

    Patient problems: Unspecified Infection

    MAUDE report 20264656 ↗
  • InjuryJul 13, 2023Naturally Worn; Naturally Worn

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2021, A PATIENT REQUIRED REVISION SURGERY DUE TO CUFF INSUFFICIENCY / GLENOID IMPLANT WEAR, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE : SINGLE STAGE REVISION.

    Patient problems: Insufficient Information

    MAUDE report 17317627 ↗
  • InjuryApr 14, 2023Difficult to Remove; Difficult to Remove

    IT WAS REPORTED THAT THERE WAS A PATIENT UNDERWENT A TOTAL SHOULDER REPLACEMENT. DUE TO INCREASING INSTABILITY IN JOINT OVER RECENT MONTHS, SURGEON DECIDED TO CONVERT THE TSA TO A REVERSE SHOULDER REPLACEMENT. ALL COMPONENTS WERE WELL FIXED. THE GLENOID POLY IMPLANT HAD TO BE BROKEN UP IN-SITU AND REMOVED IN PIECES. THE HUMERAL COMPONENT WAS EXTREMELY WELL FIXED. SIGNIFICANT BONE WAS ATTACHED TO THE CENTRAL CORE/FINS OF THE COMPONENT. A REVERSE ARTHROPLASTY PROSTHESIS WAS IMPLANTED. STABILE RANGE OF MOTION WAS DEMONSTRATED AT THE CONCLUSION OF SURGERY.

    Patient problems: Joint Laxity

    MAUDE report 16743225 ↗

Other Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained devices

All Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained devices →