Tornier Simpliciti Shoulder SystemRecalls & reported problems across all models
Tornier, Inc. · 8 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 34
- Deaths reported
- 0
- Injuries reported
- 34
- Recalls
- 0
We found 8 models of Tornier Simpliciti Shoulder System by Tornier, Inc. in the FDA's device registry (GUDID). Together they are named in 34 adverse event reports in the FDA's MAUDE database, received between Jun 8, 2022 and May 12, 2026 — classified as 34 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported Tornier Simpliciti Shoulder System problems
Device problems
- Adverse Event Without Identified Device or Use Problem25
- Device Dislodged or Dislocated3
- Naturally Worn2
- Unstable2
- Difficult to Remove1
- Migration1
Patient problems
- Implant Pain9
- Unspecified Infection5
- Erosion4
- Bacterial Infection3
- Joint Laxity3
- Loss of Range of Motion3
- Muscle/Tendon Damage3
- Bone Fracture(s)2
Tornier Simpliciti Shoulder System models
8 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Tornier Simpliciti® Shoulder System 7122872Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained9 reports
- Tornier Simpliciti® Shoulder System 7122871Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained5 reports
- Tornier Simpliciti® Shoulder System 7122876Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained5 reports
- Tornier Simpliciti® Shoulder System 7122874Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained4 reports
- Tornier Simpliciti® Shoulder System DWG401Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained4 reports
- Tornier Simpliciti® Shoulder System 7122870Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained3 reports
- Tornier Simpliciti® Shoulder System 7122868Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained3 reports
- Tornier Simpliciti® Shoulder System 7122873Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 report
Recent Tornier Simpliciti Shoulder System adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjuryMay 12, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, THE PATIENT UNDERWENT A RIGHT PRIMARY ANATOMIC SHOULDER REPLACEMENT ON (B)(6) 2024. ADVISED BY SURGEON YESTERDAY THAT THE PATIENT NOW REQUIRES A REVISION (REMOVAL OF ALL IMPLANTS), AND CONVERSION TO A REVERSE SHOULDER REPLACEMENT, AS THE PATIENT'S ROTATOR CUFF HAS FAILED. THE SURGERY WAS SCHEDULED FOR (B)(6) 2026. RIGHT PRIMARY SHOULDER ARTHROPLASTY ON 6.8.24. PATIENT HAD BEEN COMPLAINING OF DISCOMFORT IN PROSTHETIC RIGHT SHOULDER JOINT APPROX 6 MONTHS POST-OP. X-RAY AT THIS TIME SHOWED SOME EVIDENCE OF LUCENCY AROUND GLENOID COMPONENT. CT SCAN AT 12 MONTHS POST-OP SHOWED INCREASING LUCENCY, HE COMPLAINED OF MORE DISCOMFORT. CT SCAN LATE 2025 SHOWED LOOSE GLENOID COMPONENT, REVISION SURGERY BOOKED. SIMPLICITI HEAD REMOVED, SIMPLICITI NUCLEUS WAS SOLID, BUT THE REVISION TOOLS GOT IT OUT QUITE CLEAN. MINIMAL BONE LOSS. GLENOID PERFORM PLUS POLY WAS VERY LOOSE, CAVITY BEHIND IT. COMPONENT HAD MINIMAL CEMENT STILL ADHERED TO IT. MULTIPLE TISSUE SAMPLES TAKEN, THOUGH SURGEON STATED THAT THERE WERE NO CLINICAL SIGNS OF INFECTION. COPIOUS LAVAGE. SHOULDER JOINT REDUCED, STABLE THROUGH FULL RANGE OF MOTION. EXPLANTED PROSTHESIS BEING RETURNED (IN A STERI-PEEL PKT) WIT
Patient problems: Discomfort; Muscle/Tendon Damage
MAUDE report 25152861 ↗InjuryMar 10, 2026Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2026. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO NATIVE GLENOID SURFACE EROSION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Erosion
MAUDE report 24560655 ↗InjuryMar 3, 2026Unstable
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2021 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION & INSTABILITY, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Joint Laxity; Unspecified Infection
MAUDE report 24494105 ↗InjuryMar 3, 2026Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2019 A PATIENT REQUIRED REVISION SURGERY DUE TO STIFFNESS & UNEXPLAINED PAIN, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Loss of Range of Motion; Pain
MAUDE report 24494100 ↗InjuryFeb 27, 2026Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED IN 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Unspecified Infection
MAUDE report 24469194 ↗InjuryFeb 24, 2026Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE HEMI SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED IN 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO NATIVE GLENOID SURFACE EROSION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Erosion
MAUDE report 24428904 ↗InjuryOct 20, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO PERIPROSTHETIC FRACTURE, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Bone Fracture(s)
MAUDE report 23334530 ↗InjuryAug 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, THE REVISION SURGERY WAS PERFORMED IN WHICH ANATOMIC SHOULDER WAS REVISED TO REVERSE DUE TO SUBSCAPULARIS REPAIR FAILING. NO IMPLANT FAILURE WAS NOTED.
Patient problems: Muscle/Tendon Damage
MAUDE report 22913092 ↗InjuryJun 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT A PATIENT REQUIRED REVISION SURGERY DUE TO UNEXPLAINED PAIN, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Implant Pain
MAUDE report 22178997 ↗InjuryApr 22, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO NATIVE GLENOID SURFACE EROSION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Erosion
MAUDE report 21879844 ↗InjuryApr 22, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL MARCH 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025, A PATIENT REQUIRED REVISION SURGERY DUE TO NATIVE GLENOID SURFACE EROSION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.
Patient problems: Erosion
MAUDE report 21879776 ↗InjuryJan 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "SUBJECT: (B)(6) SHOUT CLINICAL STUDY DEEP INFECTION. PATIENT UNDERWENT A REVISION L TSA WITH EXCHANGE OF SIMPLICITI HEAD TO TORNIER STEM IMPLANT."
Patient problems: Unspecified Infection
MAUDE report 21122543 ↗InjuryJan 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "SUBJECT (B)(6) SHOUT - TORNIER SHOULDER OUTCOMES STUDY PATIENT REPORTED PAIN IN THE SHOULDER AFTER POWER WASHING".
Patient problems: Implant Pain
MAUDE report 21122536 ↗InjuryJan 2, 2025Unstable; Unstable
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED UNTIL (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO INSTABILITY, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: SINGLE STAGE REVISION.
Patient problems: Joint Laxity
MAUDE report 21055890 ↗InjuryJan 2, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED UNTIL AUGUST 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024, A PATIENT REQUIRED REVISION SURGERY DUE TO NATIVE GLENOID SURFACE EROSION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: SINGLE STAGE REVISION.
Patient problems: Bone Shedding Debris
MAUDE report 21055687 ↗
Other Tornier, Inc. products
- Tornier Perform Reversed Glenoid41 models · 515 reports · 1 recall
- Tornier Perform40 models · 290 reports · 1 recall
- TORNIER PERFORM HUMERAL SYSTEM68 models · 190 reports · 1 recall
- Tornier HRS40 models · 176 reports · 1 recall
- Tornier Perform Reversed Augmented Glenoid8 models · 121 reports · 1 recall
- AEQUALIS FLEX REVIVE24 models · 70 reports · 2 recalls
- Latitude - Elbow35 models · 147 reports
- Tornier Latitude7 models · 14 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page