Skip to content

Tornier Perform® Reversed Glenoid DWJ714Recalls & reported problems

Tornier, Inc. · Peripheral Screw · Class 2 · Implant

All models of Tornier Perform Reversed Glenoid (41)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00846832091218), received between Jan 19, 2023 and Sep 11, 2026 — classified as 4 injuries.

The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Loosening of Implant Not Related to Bone-Ingrowth2

Patient problems

  • Insufficient Information2
  • Bacterial Infection1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjurySep 11, 2026Loosening of Implant Not Related to Bone-Ingrowth

    As reported: "Yesterday, the surgeon performed a revision for Pt F G. The glenoid had become unstable and the entire Perform+ construct (baseplate+post+peripheral screws+glenosphere) came out and rotated down. He removed the tray and liner from the humeral components, and due to the stem being well fixed, placed a cobolt-chrome head on instead making it a hemi construct."

    Patient problems: Insufficient Information

    MAUDE report 50735212 ↗
  • InjurySep 11, 2026Loosening of Implant Not Related to Bone-Ingrowth

    As reported: "Yesterday, the surgeon performed a revision for Pt F G. The glenoid had become unstable and the entire Perform+ construct (baseplate+post+peripheral screws+glenosphere) came out and rotated down. He removed the tray and liner from the humeral components, and due to the stem being well fixed, placed a cobolt-chrome head on instead making it a hemi construct."

    Patient problems: Insufficient Information

    MAUDE report 50735031 ↗
  • InjuryJun 5, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE REVERSE SHOULDER ARTHROPLASTY WAS DONE FOR INFECTION. THE SURGEON MENTIONED ENTEROCOCCI WAS DETECTED. THE IMPLANTS WERE REMOVED AND CEMENT SPACER WAS IMPLANTED. NO PRODUCT FAULT WAS REPORTED.

    Patient problems: Bacterial Infection

    MAUDE report 22154006 ↗
  • InjuryJan 19, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    INFECTION WAS FOUND IN A PATIENT AFTER ARTIFICIAL SHOULDER JOINT SURGERY.

    Patient problems: Unspecified Infection

    MAUDE report 16203347 ↗

Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices

All PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page