ConcertoTM PV-14-40-HELIXRecalls & reported problems

Micro Therapeutics, Inc. · PV-14-40-HELIX CONCERTO PGLA COIL · Class 2 · Implant

All models of ConcertoTM (70)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00847536017047), received between Jan 3, 2019 and Jan 3, 2019 — classified as 1 injury.

The most frequently reported specific device problem is “Migration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Migration1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 3, 2019Migration; Migration

    MEDTRONIC RECEIVED A REPORT OF CONCERTO COIL THAT MIGRATED POST PROCEDURE TO THE AXILAR ARTERY AFTER BEING IMPLANTED IN THE CORRECT LOCATION. THE ISSUE WAS NOTICED THE DAY AFTER PROCEDURE AND RESULTED IN PATIENT INJURY. IT IS UNKNOWN WHAT THE CAUSE OF MIGRATION WAS. THE PATIENT UNDERWENT COILING EMBOLIZATION OF OCCLUSION OF LEFT SUBCLAVIA ARTERY. THE VESSEL WAS NORMAL TORTUOUS AND BLOOD FLOW WAS LOW. IT WAS REPORTED THAT THE CONCERTO COIL WAS IMPLANTED AT INTENDED LOCATION. AFTER THE IMPLANTATION OF A TORACICA ENDOPROTESIS. THE COIL IN THE CONTROL IS PLACED IN THE RIGHT PLACE AND IN GOOD CONDITION. THE DURING DAY CHECK THE ARM AND OBSERVE THE MIGRATED COIL TO THE AXILLAR ARTERY. THERE WERE NOT ANY PATIENT SYMPTOMS OR COMPLICATIONS ASSOCIATED WITH THIS EVENT. YES, THE EVENT LEAD O PATIENT HOSPITALIZATION. REPORTED DEVICE AND ANY ACCESSORY DEVICES WERE PREPARED AS INDICATED IN THE IFU. THE COIL WAS IMPLANTED AT THE INTENDED LOCATION. ACCESSORY DEVICES WILL NOT BE RETURNED AS HOSPITAL DOSE NOT ALLOW. ANCILLARY DEVICES INCLUDE AN INTRODUCTOR DIAGNOSTICO 7 FR, CATHETER MULTIPROPOSITO 5FR.

    Patient problems: Foreign Body In Patient

    MAUDE report 8214271 ↗

Other Device, Vascular, for Promoting Embolization devices