AxiumTM QC-7-30-3DRecalls & reported problems
Micro Therapeutics, Inc. · COIL QC-7-30-3D V04 AXIUM · Class 2 · Implant
All models of AxiumTM (139)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00847536030060), received between Feb 3, 2022 and Jan 18, 2024 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).
2 other recalls cover devices cleared under the same FDA submission (K081465); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component3
- Physical Resistance/Sticking1
- Separation Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 18, 2024Detachment of Device or Device Component; Physical Resistance/Sticking; Detachment of Device or Device Component; Physical Resistance/Sticking
MEDTRONIC RECEIVED A REPORT THAT THIS PATIENT HAD AN INTRACRANIAL ANEURYSM. DURING THE SURGICAL FILLING OF THE SPRING COIL, IT WAS FOUND THAT THE QC2-6-3D COULD NOT BE PUSHED. AFTER REPLACEMENT, THE PUSH WENT SMOOTHLY. THE COIL WAS STUCK IN THE MIDDLE OF THE CATHETER. THERE WAS NO DAMAGE OBSERVED ON THE CATHETER OR COIL. DURING THE SURGERY, IT WAS DISCOVERED THAT THE QC-7-30-3D SPRING COIL HAD DETACHED AUTOMATICALLY. THERE WAS NO SURGICAL OR MEDICINAL INTERVENTION REQUIRED. THE PUSHWIRE WAS NOT BENT OR BROKEN. THERE WAS FRICTION OF DIFFICULTY DURING DELIVERY. THE PHYSICIAN REPOSITIONED THE COIL TWICE. THE PHYSICIAN DID NOT ATTEMPT TO DETACH THE COIL. THE PHYSICIAN DID NOT ROTATE THE DELIVERY PUSHER DURING THE PROCEDURE. CONTINUOUS FLUSH WAS ADMINISTERED DURING THE PROCEDURE. NO PATIENT SYMPTOMS OR FURTHER COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT. THE DEVICE AND ANY ACCESSORIES WERE PREPARED AS INDICATED IN THE IFU. THE PATIENT WAS UNDERGOING SURGERY FOR TREATMENT OF A SACCULAR, RUPTURED RIGHT ANTERIOR COMMUNICATING ARTERY ANEURYSM WITH A MAX DIAMETER OF 4.0MM AND A 2.0MM NECK DIAMETER. IT WAS NOTED THE PATIENT'S BLOOD FLOW WAS NORMAL AND VESSEL TORTUOSITY WAS MODERATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18535441 ↗MalfunctionMay 6, 2022Detachment of Device or Device Component; Detachment of Device or Device Component
MEDTRONIC RECEIVED INFORMATION THAT AN AXIUM COIL PREMATURELY DETACHED. THE PATIENT WAS BEING TREATED FOR A NEUROVASCULAR ABNORMALITY. IT WAS NO IN THE ELOQUENT REGION. PATIENT BLOOD FLOW WAS NORMAL AND VESSEL TORTUOSITY WAS MODERATE. THE DEVICES WERE PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). WHILE THE COIL WAS BEING DEPLOYED ON THE ARTERIOVENOUS FISTULA (AVF) LESION, IT WAS DETACHED IN ADVANCE AND PUSHED INTO THE MICROCATHETER. THE COIL WAS IMPLANTED AT THE INTENDED LOCATION AND REMAIN IN THE PATIENT. NO SURGICAL OR MEDICAL INTERVENTION WAS REQUIRED. THE PUSHWIRE WAS NOT BENT OR BROKEN. THERE WAS NO FRICTION OR DIFFICULTY DURING DEPLOYMENT. THE PHYSICIAN DID NOT REPOSITION THE COIL. THEY DID NOT ATTEMPT TO DETACH THE COIL. THEY DID NOT ROTATE THE DELIVERY PUSHER DURING THE PROCEDURE. CONTINUOUS FLUSH WAS ADMINISTERED DURING THE PROCEDURE. NO SYMPTOMS WERE REPORTED. ANCILLARY DEVICES: SL10 MICROCATHETER ADDITIONAL INFORMATION RECEIVED REPORTED THE EVENT INVOLVED TWO DIFFERENT AXIUM COILS WITH THE SAME LOT NUMBER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14311276 ↗MalfunctionMar 20, 2022Detachment of Device or Device Component; Detachment of Device or Device Component
MEDTRONIC RECEIVED INFORMATION THAT AN AXIUM COIL PREMATURELY DETACHED. THE PATIENT WAS BEING TREATED FOR A NEUROVASCULAR ABNORMALITY. IT WAS NO IN THE ELOQUENT REGION. PATIENT BLOOD FLOW WAS NORMAL AND VESSEL TORTUOSITY WAS MODERATE. THE DEVICES WERE PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). WHILE THE COIL WAS BEING DEPLOYED ON THE ARTERIOVENOUS FISTULA (AVF) LESION, IT WAS DETACHED IN ADVANCE AND PUSHED INTO THE MICROCATHETER. THE COIL WAS IMPLANTED AT THE INTENDED LOCATION AND REMAIN IN THE PATIENT. NO SURGICAL OR MEDICAL INTERVENTION WAS REQUIRED. THE PUSHWIRE WAS NOT BENT OR BROKEN. THERE WAS NO FRICTION OR DIFFICULTY DURING DEPLOYMENT. THE PHYSICIAN DID NOT REPOSITION THE COIL. THEY DID NOT ATTEMPT TO DETACH THE COIL. THEY DID NOT ROTATE THE DELIVERY PUSHER DURING THE PROCEDURE. CONTINUOUS FLUSH WAS ADMINISTERED DURING THE PROCEDURE. NO SYMPTOMS WERE REPORTED. ANCILLARY DEVICES: SL10 MICROCATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13834626 ↗MalfunctionFeb 3, 2022Separation Failure; Separation Failure
MEDTRONIC RECEIVED A REPORT THAT THE COIL WAS NOT ABLE TO BE DETACHED. THE PHYSICIAN ATTEMPTED TO DETACH THE COIL WITH THE DETACHER TWO TIMES. THE PHYSICIAN DID NOT TRY TO DETACH WITH ANOTHER INSTANT DETACHER. THERE WERE TWO MANUAL ATTEMPTS TO DETACH VIA HYPOTUBE. THE REPORTED DEVICE AND ANY ACCESSORY DEVICES PREPARED AS INDICATED IN IFU. NO PATIENT SYMPTOMS OR FURTHER COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT. THE PATIENT WAS UNDERGOING SURGERY FOR TREATMENT OF A SACCULAR, UNRUPTURED ANEURYSM IN THE P-COM WITH A MAX DIAMETER OF 7MM AND A 3MM NECK DIAMETER. IT WAS NOTED THE PATIENT'S BLOOD FLOW WAS NORMAL AND VESSEL TORTUOSITY WAS MODERATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13443244 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K081465. One submission often covers many models, so check the product and lot details in each record.
- Z-0873-2012 · Mar 1, 2010 · TerminatedAxium Detachable Coil System QC-2-1-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular ab
- Z-0874-2012 · Mar 1, 2010 · TerminatedAxium Detachable Coil System QC-7-30-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular a
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page