ConcertoTM PV-14-30-HELIX (UDI 00847536033641)Recalls & reported problems
Micro Therapeutics, Inc. · COIL PV-14-30-HELIX V06 · Class 2 · Implant
All models of ConcertoTM (70)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00847536033641), received between Mar 5, 2021 and Feb 2, 2024 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component2
- Separation Failure2
- Migration1
- Packaging Problem1
- Positioning Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Aneurysm1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 2, 2024Detachment of Device or Device Component; Packaging Problem; Detachment of Device or Device Component; Packaging Problem
MEDTRONIC RECEIVED A REPORT THAT THE BOX WHERE THE INPUT CAME WAS SEALED. THE CORRESPONDING OPENING WAS MADE AND WHEN OPENING THE PA CKAGING, A COIL WAS OBSERVED OUTSIDE THE MANDREL. THE DEVICE WAS NOT USED SUCCESSFULLY. HEALTHCARE PROVIDER (HCP) PULLED IT OUT AND USED ANOTHER ONE. ALL PIECES WERE NOT ACCOUNTED FOR. THE INPUT WAS OUTSIDE THE MANDRIL. A NEW COIL WAS USED. NO ADDITIONAL TREATMENT WAS REQUIRED. THIS DEVICE WAS REPROCESSED. THE LUMEN WAS NOT FLUSHED PRIOR TO USE. INSTRUCTIONS FOR USE (IFU) WAS FOLLOWED DURING PREPARATION, PROCEDURE, AND POST PROCEDURE. PROPER TEMPERATURE WAS REACHED. NO PATIENT SYMPTOMS OR FURTHER COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT. THERE WAS NO MEDICAL OR SURGICAL INTERVENTION NEEDED TO PREVENT PERMANENT IMPAIRMENT OF A FUNCTION. THIS EVENT DID NOT LEAD TO OR EXTEND PATIENT HOSPITALIZATION. TUMESCENT INFILTRATION WAS UTILIZED. LOCAL ANESTHESIA WAS USED. HAND COMPRESSION WAS USED. THE VEIN CLOSED. 1 SEGMENT WAS TREATED. ADDITIONAL INFORMATION RECEIVED REPORTED CLARIFICATION THAT WHEN THE COIL WAS TAKEN FROM THE PACKAGING IT WAS DETACHED. THE PROXIMAL END OF THE PUSHWIRE WAS SECURED IN THE GUIDEWIRE CLIP (BLACK RUBBER STOPPER) WHEN TH
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18634256 ↗MalfunctionMar 3, 2022Detachment of Device or Device Component; Detachment of Device or Device Component
MEDTRONIC RECEIVED INFORMATION THAT THE CONCERTO COIL DETACHED WHEN THE PHYSICIAN DID NOT DETACH ATTEMPT TO DETACH. VESSEL TORTUOSITY WAS MODERATE. THE DEVICES WERE PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). ANOTHER CONCERTO COIL WAS USED. NO SYMPTOMS WERE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13665003 ↗MalfunctionMar 3, 2022Separation Failure; Separation Failure
MEDTRONIC RECEIVED A REPORT THAT THE CONCERTO COIL COULD NOT BE DETACHED. THE PHYSICIAN ALSO TRIED TO DETACH THE COIL MANUALLY. THE COIL WAS REPLACED, AND THE PATIENT DID NOT EXPERIENCE ANY INJURY OR COMPLICATIONS. THE DEVICES WERE PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THE PATIENT WAS UNDERGOING TREATMENT FOR ANEURYSM EMBOLIZATION. THE PATIENT'S VESSEL TORTUOSITY WAS MODERATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13662144 ↗MalfunctionJun 4, 2021Separation Failure; Separation Failure
IT WAS REPORTED THAT THE COIL WAS BEING USED AS PER THE IFU; HOWEVER, THE COIL DID NOT DETACH FROM ITS WIRE WITH EITHER THE INSTANT DETACHER OR MANUAL METHOD. A NEW COIL WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT SYMPTOMS ASSOCIATED WITH THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11939973 ↗InjuryMar 5, 2021Positioning Problem; Migration; Positioning Problem; Migration
ADDITIONAL INFORMATION RECEIVED REPORTED THE PATIENT DID NOT RECEIVE ANY ANTIPLATELET REGIMEN.
Patient problems: Aneurysm
MAUDE report 11424037 ↗
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page