ConcertoTM PV-10-30-3D (UDI 00847536033825)Recalls & reported problems
Micro Therapeutics, Inc. · COIL PV-10-30-3D V04 · Class 2 · Implant
All models of ConcertoTM (70)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00847536033825), received between Jun 1, 2022 and Apr 13, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Physical Resistance/Sticking2
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 13, 2023Detachment of Device or Device Component; Physical Resistance/Sticking; Detachment of Device or Device Component; Physical Resistance/Sticking
MEDTRONIC RECEIVED A REPORT THAT A CONCERTO COIL WAS STUCK IN THE REBAR CATHETER AND PREMATURELY DETACHED. THE PATIENT WAS UNDERGOING AN EMBOLIZATION FOR TREATMENT OF AN UNRUPTURED, RENAL ANEURYSM WITH A MAX DIAMETER OF 28 MM AND A 9 MM NECK DIAMETER. ACCESSED VESSEL WAS 1. IT WAS NOTED THE PATIENT'S BLOOD FLOW WAS UNKNOWN AND VESSEL TORTUOSITY WAS NORMAL. IT WAS REPORTED THAT THE REBAR CATHETER (LOT # B461082) WAS KINKED. IT WAS ALSO REPORTED THE CONCERTO COIL WAS STUCK INSIDE THE MICROCATHETER. THERE WAS CATHETER RESISTANCE IN THE PROXIMAL SECTION OF THE CATHETER. IT WAS REPORTED THE CONCERTO COIL PREMATURELY DETACHED. IT WAS REPORTED THERE WAS COIL RESISTANCE/STUCK IN THE MIDDLE SECTION OF THE CATHETER. THE CATHETER WAS NOT DAMAGED. THE COIL WAS DAMAGED ON THE PUSHWIRE IN THE DISTAL SEGMENT. IT WAS REPORTED COIL SEPARATION/BREAK/PREMATURE DETACHMENT OCCURRED. THE COIL WAS REMOVED FROM THE PATIENT BY PUSHING OUT FROM THE MICROCATHETER. THERE WAS NO SURGICAL OR MEDICINAL INTERVENTION REQUIRED. THE PUSHWIRE WAS NOT BENT OR BROKEN. THERE WAS FRICTION OR DIFFICULTY DURING DELIVERY. THE PHYSICIAN DID NOT REPOSITION THE COIL. THE PHYSICIAN DID NOT ATTEMPT TO DETACH THE COIL. THE PHYSIC
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16732779 ↗MalfunctionJun 1, 2022Physical Resistance/Sticking; Physical Resistance/Sticking
MEDTRONIC RECEIVED INFORMATION THAT A CONCERTO COIL WAS STUCK IN THE MIDDLE OF THE CATHETER. THE PATIENT WAS BEING TREATED FOR A GASTROINTESTINAL BLEED. PATIENT BLOOD FLOW AND VESSEL TORTUOSITY WAS NORMAL. THE DEVICES WERE PREPARED AS INDICATED IN THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DAMAGE TO THE CATHETER OR COIL. NO SYMPTOMS WERE REPORTED. ADDITIONAL INFORMATION RECEIVED REPORTED THAT THE COIL COME OUT OF THE INTRODUCER SHEATH SMOOTHLY. THERE WAS NO KINK/DAMAGE TO THE COIL OBSERVED AFTER REMOVAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14565203 ↗
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page