Axium Prime Detachable Coil System APB-5-10-HX-SSRecalls & reported problems
Micro Therapeutics, Inc. · COIL APB-5-10-HX-SS V05 · Class 2 · Implant
All models of Axium Prime Detachable Coil System (70)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00847536038561), received between Jul 26, 2023 and Jun 28, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K081465); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Physical Resistance/Sticking2
- Break1
- Migration1
- Unintended Movement1
Patient problems
- Failure of Implant1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 28, 2024Unintended Movement; Migration; Physical Resistance/Sticking; Unintended Movement; Migration; Physical Resistance/Sticking
ADDITIONAL INFORMATION RECEIVED THAT THIS WAS THE FIRST TIME THAT THE HOSPITAL'S CARDIOVASCULAR DEPARTMENT USED MEDTRONIC AXIUM COILS. THREE COILS WERE SUBSEQUENTLY USED, WITH SPECIFICATIONS OF 3-8, 3-8, AND 3-10. THE COIL FLEW OUT BECAUSE IT WAS NOT PROPERLY COILED WHEN FORMING HOOP AND IT DID NOT STRETCH AUTOMATICALLY. THE COIL WAS REMOVED ON THE DAY OF THE SURGERY.
Patient problems: Failure of Implant
MAUDE report 19634084 ↗MalfunctionJul 26, 2023Break; Physical Resistance/Sticking; Break; Physical Resistance/Sticking
ADDITIONAL INFORMATION WAS RECEIVED THAT THE COIL PUSHED OUT OF THE INTRODUCER SHEATH WITH A LITTLE RESISTANCE. CATHETER RESISTANCE OCCURRED IN THE MIDDLE SECTION. THE CATHETER WAS AN ECHELON CATHETER. THERE WAS NO KINK/DAMAGE OBSERVED TO THE CATHETER AFTER REMOVAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17396449 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K081465. One submission often covers many models, so check the product and lot details in each record.
- Z-0873-2012 · Mar 1, 2010 · TerminatedAxium Detachable Coil System QC-2-1-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular ab
- Z-0874-2012 · Mar 1, 2010 · TerminatedAxium Detachable Coil System QC-7-30-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular a
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page