Axium Prime Detachable Coil System FC-8-20-3DRecalls & reported problems

Micro Therapeutics, Inc. · COIL FC-8-20-3D V05 · Class 2 · Implant

All models of Axium Prime Detachable Coil System (70)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00847536038851), received between Aug 12, 2022 and Aug 12, 2022 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break1
  • Detachment of Device or Device Component1
  • Stretched1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 12, 2022Break; Stretched; Detachment of Device or Device Component; Break; Stretched; Detachment of Device or Device Component

    MEDTRONIC RECEIVED A REPORT THAT THREE COILS PREMATURELY DETACHED. THE PATIENT WAS UNDERGOING TREATMENT FOR A RUPTURED, SACCULAR ANEURYSM LOCATED IN THE RIGHT INTERNAL CAROTID ARTERY SIPHON. THE MAX DIAMETER WAS 12.3MM, AND THE NECK DIAMETER WAS 8.3MM. THE PATIENT'S BLOOD FLOW WAS NORMAL, AND THEIR VESSEL TORTUOSITY WAS MODERATE. IT WAS REPORTED THAT THERE WAS A LOT OF RESISTANCE WHEN THE SPRING COIL (FC-12-40-3D) WAS PUSHED FROM THE PROTECTIVE SHEATH INTO THE MICROCATHETER. THE SURGEON WITHDREW THE DELIVERY GUIDE WIRE AND PLANNED TO TAKE OUT PART OF THE SPRING COIL FOR OBSERVATION. AFTER THE DELIVERY GUIDE WIRE WAS WITHDRAWN FROM THE MICROCATHETER, IT WAS FOUND THAT IT WAS DETACHED AND THE COIL BODY REMAINED IN THE MICROCATHETER. THE COIL WAS REMOVED WITHOUT FURTHER INTERVENTION. THE PUSHWIRE WAS NOT BENT/BROKEN, THE PHYSICIAN DID NOT REPOSITION THE COIL, NO DETACHMENTS HAD BEEN MADE, AND THE DELIVERY PUSHER WAS NOT ROTATED. DURING THE PROCESS OF FILLING THE ANEURYSM WITH ANOTHER SPRING COIL (FC-8-20-3D), THE SURGEON TRIED TO ADJUST THE POSITION OF THE SPRING COIL INTO THE LOOP. DURING ADJUSTMENT, IT WAS FOUND THAT THE SPRING COIL WAS DETACHED. AT THIS TIME, PART OF THE SPRING COI

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 15218009 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →