BioPlex 2200 6653250Recalls & reported problems

Bio-Rad Laboratories, Inc. · Anti-CCP Reagent Pack · Class 2

All models of BioPlex 2200 (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00847865000857), received between Feb 22, 2023 and Feb 22, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “False Positive Result” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Recalls naming this device

  1. Feb 21, 2023Class IIOpen, Classified

    Bio-Rad received four customer complaints from 11/30/2022 to 12/21/2022 on BioPlex 2200 Anti-CCP Kit (Lot 301481) stating that results were discrepant while performing lot-to-lot validation against previous lots. Internal testing at Bio-Rad has demonstrated that Lot No. 301481 exhibits a specificity of 94.5% (95% CI 91.8 96.4) whereas the IFU indicates a specificity of 97.8% (95% CI 96.1 98.8%). The reduction in specificity may lead to an increase in the number of false positives.

    Z-1377-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • False Positive Result1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 22, 2023False Positive Result; False Positive Result

    BIO-RAD LABORATORIES HAS RECEIVED REPORTS OF DISCREPANT RESULTS WITH LOT NO. 301481 FROM FOUR CUSTOMERS PERFORMING LOT-TO-LOT VALIDATION AGAINST PREVIOUS LOTS. INTERNAL TESTING AT BIO-RAD HAS DEMONSTRATED THAT LOT NO. 301481 EXHIBITS A REDUCTION IN SPECIFICITY (POTENTIAL FOR FALSE POSITIVE RESULTS). THERE WERE NO REPORTED ADVERSE EVENT WITH THIS LOT. HOWEVER,FALSE POSITIVE ANTI-CCP RESULTS COULD LEAD TO INCORRECT DIAGNOSIS OF RHEUMATOID ARTHRITIS AND UNNECESSARY MEDICAL TREATMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16422988 ↗

Other ANTIBODIES, ANTI-CYCLIC CITRULLINATED PEPTIDE (CCP) devices

All ANTIBODIES, ANTI-CYCLIC CITRULLINATED PEPTIDE (CCP) devices →