MODULAR FLEXIBLE REAMER HEAD, Ø15.5mm 0234-155Recalls & reported problems
Advanced Orthopaedic Solutions, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00848665000986), received between Feb 10, 2026 and Feb 10, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 10, 2026Break
ON 17-JAN-2026, A FACILITY REPRESENTATIVE REPORTED VIA (B)(4) THAT A 0234-155 15.5 MM MODULAR FLEXIBLE REAMER HEAD BROKE DURING THE INTRAMEDULLARY REAMING OF A FEMORAL SHAFT. THE HIP NAIL PROCEDURE WAS COMPLETED SUCCESSFULLY; HOWEVER, THE BROKEN PIECE WAS NOT RETRIEVED FROM THE PATIENT. IT WAS REPORTED THAT THERE WAS NO OTHER PATIENT HARM. ADDITIONAL INFORMATION WAS RECEIVED ON 04-FEB-2026. THE REP ADVISED THAT THERE WERE TWO SMALL FRAGMENTS CREATED IN ADDITION TO THE LARGER REMAINING PORTION OF THE REAMER THAT WAS RETRIEVED, AND THOSE TWO FRAGMENTS REMAINED IN THE PATIENT. THE REP STATED THAT NO ATTEMPT WAS MADE TO RETRIEVE THE FRAGMENTS, AS THEY WERE MIDSHAFT AND DEEMED IMPOSSIBLE TO RETRIEVE. THERE WAS NO DELAY ENCOUNTERED.
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 24308866 ↗
Other Rod, Fixation, Intramedullary And Accessories devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page