AOS ANTEGRADE FEMORAL NAIL, LEFT 10mm x 40cm 1310-040Recalls & reported problems
Advanced Orthopaedic Solutions, Inc. · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00848665017366), received between Mar 7, 2024 and Mar 7, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
Patient problems
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 7, 2024Fracture; Fracture
ON 2/20/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA PHONE THAT A 1310-040 ANTEGRADE FEMORAL NAIL HAD BEEN CRACKED INSIDE THE PATIENT AND WAS EXPERIENCING PAIN, WHICH WAS CONFIRMED BY AN X-RAY DONE ON THE PATIENT LAST WEEK. DURING THE ORIGINAL PROCEDURE OF AN ORIF LEFT FEMUR FRACTURE PROCEDURE ON (B)(6) 2023, A (1) 1310-040 ANTEGRADE FEMORAL NAIL/BATCH: 462737, (1) 8001-050 CAPTURED CORTICAL SCREW/BATCH: UNKNOWN / (1) 8001-055 CAPTURED CORTICAL SCREW/BATCH: UNKNOWN, (2) 8065-085 CANCELLOUS SCREW/BATCH: UNKNOWN AND BATCH: 472747, (1) 8065-090 CANCELLOUS SCREW/BATCH: 220505 ARTHREX PRODUCTS WERE IMPLANTED. THE ORIGINAL PROCEDURE HAD NO ISSUES REPORTED AND WAS COMPLETED SUCCESSFULLY. THE REMOVAL OF HARDWARE AND REPAIR OF THE LEFT FEMORAL ORIF FRACTURE REVISION PROCEDURE OCCURRED ON 2/20/2024. THE ARTHREX PRODUCTS THAT WERE EXPLANTED WERE (1) 1310-040 ANTEGRADE FEMORAL NAIL/BATCH: 462737, (1) 8001-050 CAPTURED CORTICAL SCREW/BATCH: UNKNOWN / (1) 8001-055 CAPTURED CORTICAL SCREW/BATCH: UNKNOWN, (2) 8065-085 CANCELLOUS SCREW/BATCH: UNKNOWN AND BATCH: 472747, (1) 8065-090 CANCELLOUS SCREW/BATCH: 220505. ADDITIONAL INFORMATION FOR THE ARTHREX PRODUCTS IMPLANTED DURING THE REVISION H
Patient problems: Pain
MAUDE report 18857694 ↗
Other Rod, Fixation, Intramedullary And Accessories devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page