Skip to content

INTERA AP-04009Recalls & reported problems

Intera Oncology Inc. · Non-coring (Huber) needle for use with Intera Infusion Pumps, Straight, 22 Gauge, 1 inch · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00850014110017), received between May 14, 2025 and May 14, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 14, 2025Fluid/Blood Leak; Fluid/Blood Leak

    INTERA ONCOLOGY RECEIVED A REPORT OF A REFILL KIT LEAK. ON (B)(6) 2025, A REPRESENTATIVE FROM INTERA ONCOLOGY WAS SUPPORTING A PUMP IMPLANTATION WITH THE CLINIC. THE SCRUB ATTACHED THE REFILL NEEDLE TO THE OR PREP KIT SYRINGE AND TUBING SET; THE SCRUB ENSURED THE TUBING AND NEEDLE CONNECTION WAS SECURE. THE SCRUB INSERTED THE NEEDLE PERPENDICULAR TO THE SEPTUM AND DEPRESSED THE NEEDLE DOWN UNTIL SHE FELT THE NEEDLE STOP. THE BACTERIOSTATIC WATER BEGAN FILLING THE SYRINGE BUT WAS SIMULTANEOUSLY LEAKING WHERE THE NEEDLE AND TUBING WERE CONNECTED. THE REPRESENTATIVE FROM INTERA ONCOLOGY ASKED THE SCRUB TO CLAMP THE TUBING, REMOVE THE NEEDLE AND CONFIRM THAT THE NEEDLE WAS TIGHT, SHE CONFIRMED IT WAS TIGHT. THE SCRUB ATTEMPTED AGAIN, AND THE WATER CONTINUED TO LEAK AT THE NEEDLE AND TUBING CONNECTION. THE SCRUB WAS INSTRUCTED BY INTERA'S REPRESENTATIVE TO REMOVE THE NEEDLE AND ATTACH THE BACKUP NEEDLE. THE SCRUB CONNECTED THE BACKUP NEEDLE AND THERE WAS NO FURTHER LEAKAGE. THE ALLEGED NEEDLE WAS SEPARATED AND SHIPPED TO INTERA ONCOLOGY HEADQUARTERS. THE NEEDLE ARRIVED AT INTERA ONCOLOGY HEADQUARTERS ON (B)(6) 2025.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22022867 ↗

FDA clearance and classification

The FDA regulates product code PTI (non-coring (huber) needle) under 21 CFR 880.5570 as a Class II device. 21 CFR 880.5570 ↗

Devices of this type normally need 510(k) clearance before sale.

FDA definition of this device type: The non-coring needle (Huber) is utilized to gain access into a subcutaneous implanted intravascular infusion port but can also be used to access other non-vascular implanted devices with similar septums.

Common questions about the INTERA AP-04009

Has the INTERA AP-04009 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00850014110017), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the INTERA AP-04009?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 14, 2025. That report lists device problem “Fluid/Blood Leak” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the INTERA AP-04009?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the INTERA AP-04009, and is it still sold?

The FDA's device database lists Intera Oncology Inc. as the company responsible for it (brand INTERA, model AP-04009). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Non-Coring (Huber) Needle devices

All Non-Coring (Huber) Needle devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page