FlexCath Cross Transseptal Solution 900308-003Recalls & reported problems

Acutus Medical, Inc. · FlexCath Cross Transseptal Solution– WT 75cm · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00850027837901), received between Jun 1, 2024 and Oct 22, 2024 — classified as 2 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Insufficient Device Problem Information1
  • Unintended Movement1

Patient problems

  • Low Blood Pressure/ Hypotension1
  • Perforation of Vessels1
  • Pericardial Effusion1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING A PROCEDURE TO PLACE A LEFT ATRIAL APPENDAGE (LAA) CLOSURE DEVICE FROM ANOTHER MANUFACTURER, THE DILATOR/TRANSSEPTAL NEEDLE AND SHEATH WERE ADVANCED INTO THE EXTERNAL ILIAC VEIN. IT WAS FURTHER REPORTED THAT PATIENT'S BLOOD PRESSURE DROPPED, AND AN EXTERNAL ILIAC VEIN PERFORATION OCCURRED. A BALLOON ANGIOPLASTY WAS PERFORMED TO STOP THE BLEEDING. THE PATIENT WAS UNDER GENERAL ANESTHESIA. THE CASE WAS ABORTED. A COMPUTERIZED TOMOGRAPHY (CT) WAS PERFORMED AND CONFIRMED THAT THE BLEEDING HAD STOPPED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. PER FOLLOW UP FROM THE REPRESENTATIVE THERE WERE NO COMPLICATIONS OR OBSERVATIONS NOTED PRIOR TO THE EVENT. NO DEVICE MALFUNCTION OR ISSUE WAS REPORTED.

    Patient problems: Low Blood Pressure/ Hypotension; Perforation of Vessels

    MAUDE report 20510372 ↗
  • InjuryJun 1, 2024Unintended Movement; Insufficient Device Problem Information; Unintended Movement; Insufficient Device Problem Information

    IT WAS REPORTED THAT DURING A CRYO ABLATION PROCEDURE, IT WAS DIFFICULT TO CROSS THE SEPTUM USING THE INTEGRATED NEEDLE/DILATOR. TWO ATTEMPTS WERE MADE TO CROSS THE SEPTUM, AND THEN THE PHYSICIAN SWITCHED TO USING RADIOFREQUENCY (RF) INSTEAD, WITHOUT RESOLUTION. THE SHEATH AND THE INTEGRATED NEEDLE/DILATOR SYSTEM WERE REMOVED. THE 0.032 AMPLATZ GUIDEWIRE REMAINED IN AND WHEN ADVANCED, IT ENTERED INTO THE LEFT ATRIUM. AFTER THE FIRST RF ATTEMPT THE PATIENT STARTED TO EXCESSIVELY COUGH AND COMPLAINED OF SHORTNESS OF BREATH. THE GUIDEWIRE WAS REMOVED AND ICE IMAGING SHOWED A SMALL EFFUSION. PROTAMINE WAS ADMINISTERED. THE PATIENT WAS STABLE WITH NORMAL VITALS WHEN LEAVING THE OPERATING ROOM. THE PATIENT WAS ADMITTED OVERNIGHT FOR OBSERVATION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Pericardial Effusion

    MAUDE report 19442198 ↗

Other Dilator, Vessel, For Percutaneous Catheterization devices

All Dilator, Vessel, For Percutaneous Catheterization devices →