Cartiva Synthetic Cartilage Implant CAR-08-USRecalls & reported problems

Cartiva, Inc · 8 mm Synthetic Cartilage Implant · Class 3 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This Cartiva synthetic cartilage implant for the toe joint has 40 adverse reports: no deaths and 40 injuries, mostly pain, failing implants, and surgical removal. There is 1 open recall started October 2024 because patients may experience higher-than-expected rates of revision, removal, subsidence, displacement, pain, nerve damage, or fragmentation. Reports dropped from 35 to 3 in the most recent 12 months.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
41
Deaths reported
0
Injuries reported
41
Recalls naming it
1

Summary

The FDA's MAUDE database contains 41 adverse event reports that list this exact device (DI 00852897002021), received between Jan 3, 2018 and Aug 19, 2026 — classified as 41 injuries.

The most frequently reported specific device problem is “Implant subsidence” (6 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 6 reportsJan 2025: 22 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 3 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202622
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 31, 2024Class IIOpen, Classified

    Patients implanted with synthetic cartilage implant, may experience a higher-than expected occurrence rate of the following hazards: revision, removal, implant subsidence, displacement, pain, nerve damage or fragmentation.

    Z-0598-2025 · Root cause: Device Design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem28
  • Implant subsidence6
  • Osseointegration Problem4
  • Collapse2
  • Insufficient Device Problem Information2
  • Loosening of Implant Not Related to Bone-Ingrowth1

Patient problems

  • Pain23
  • Failure of Implant9
  • Implant Pain8
  • Discomfort7
  • Loss of Range of Motion5
  • Inadequate Osseointegration4
  • Arthritis2
  • Deformity/ Disfigurement2

Recent adverse event reports

The 25 most recent of 41 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 19, 2026Adverse Event Without Identified Device or Use Problem

    As reported: "Patient, through counsel, alleges that she was implanted with Cartiva on the right side on (b)(6)2018. Patient underwent revision on (b)(6) 2022 due to alleged pain."

    Patient problems: Pain

    MAUDE report 50334028 ↗
  • InjuryJun 9, 2026Insufficient Device Problem Information

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT SHE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6) 2018 AND REVISED ON (B)(6) 2019 DUE TO UNSPECIFIED PRODUCT FAILURE.

    Patient problems: Insufficient Information

    MAUDE report 25446812 ↗
  • InjuryFeb 23, 2026Implant subsidence

    IT WAS REPORTED THROUGH THE FILING OF A LAWSUIT THAT ALLEGEDLY THE PATIENT HAD A CARTIVA IMPLANT PLACED IN HER LEFT FIRST MTP JOINT. CLAIMANT, THROUGH COUNSEL, ALLEGES THAT THE IMPLANT WAS SUBSEQUENTLY SURGICALLY REMOVED DUE TO PAIN AND SUBSIDENCE.

    Patient problems: Pain

    MAUDE report 24421511 ↗
  • InjuryJan 2, 2026Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT HE WAS IMPLANTED WITH CARTIVA IN HIS LEFT FIRST MTP JOINT ON (B)(6) 2017 AND HAD TO HAVE THE IMPLANT SURGICALLY REMOVED ON (B)(6) 2025.

    Patient problems: Insufficient Information

    MAUDE report 23950018 ↗
  • InjuryOct 22, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "CLAIMANT, THROUGH COUNSEL, ALLEGES THAT SHE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6) 2017 AND REVISED ON (B)(6) 2018 DUE TO PAIN".

    Patient problems: Pain

    MAUDE report 23361051 ↗
  • InjuryOct 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED BY PATIENT'S COUNSEL THAT ALLEGEDLY ON (B)(6)2018, THE PATIENT UNDERWENT BILATERAL BUNIONECTOMY AND BILATERAL CHEILECTOMY AND WAS IMPLANTED WITH 8 MM CARTIVA IMPLANTS. THE PATIENT SUBSEQUENTLY DEVELOPED SIGNIFICANT REDUCTION IN HER RANGE OF MOTION AS WELL AS PAIN TO THE JOINTS. THE PATIENT ALSO HAD SOME HALLUX ABDUCTOVALGUS DEFORMITY WHICH WAS FORMING TO BOTH GREAT TOE JOINTS. THE PATIENT UNDERWENT BILATERAL FIRST METATARSOPHALANGEAL JOINT ARTHROPLASTY ON (B)(6)2024.

    Patient problems: Deformity/ Disfigurement; Loss of Range of Motion; Pain

    MAUDE report 23246619 ↗
  • InjuryOct 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED BY PATIENT'S COUNSEL THAT ALLEGEDLY ON (B)(6) 2018, THE PATIENT UNDERWENT BILATERAL BUNIONECTOMY AND BILATERAL CHEILECTOMY AND WAS IMPLANTED WITH 8 MM CARTIVA IMPLANTS. THE PATIENT SUBSEQUENTLY DEVELOPED SIGNIFICANT REDUCTION IN HER RANGE OF MOTION AS WELL AS PAIN TO THE JOINTS. THE PATIENT ALSO HAD SOME HALLUX ABDUCTOVALGUS DEFORMITY WHICH WAS FORMING TO BOTH GREAT TOE JOINTS. THE PATIENT UNDERWENT BILATERAL FIRST METATARSOPHALANGEAL JOINT ARTHROPLASTY ON (B)(6) 2024.

    Patient problems: Deformity/ Disfigurement; Loss of Range of Motion; Pain

    MAUDE report 23246618 ↗
  • InjuryJul 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT SHE WAS IMPLANTED WITH CARTIVA IN THE RIGHT 1ST MTP JOINT ON (B)(6) 2019. PATIENT HAS NOT BEEN REVISED BUT A MEDICAL PROVIDER HAS RECOMMENDED REVISION. PATIENT ALLEGES PAIN AND LIMITED MOBILITY DUE TO THE IMPLANT.

    Patient problems: Loss of Range of Motion; Pain

    MAUDE report 22441312 ↗
  • InjuryJul 7, 2025Implant subsidence; Implant subsidence

    CLAIMANT, THROUGH COUNSEL, ALLEGES IMPLANTATION OF A CARTIVA DEVICE IN THE RIGHT GREAT TOE. ALLEGED SYMPTOMS INCLUDE PERSISTENT PAIN, DISCOMFORT, SWELLING, AND IMAGING REPORTEDLY SHOWED IMPLANT RECESSION WITH RESULTING BONE-ON-BONE CONTACT IN THE TOE JOINT.

    Patient problems: Joint Impingement; Pain; Swelling/ Edema

    MAUDE report 22417679 ↗
  • InjuryJun 30, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2019 AND REVISED ON (B)(6) 2024 DUE TO PAIN.

    Patient problems: Pain

    MAUDE report 22362308 ↗
  • InjuryMay 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ALLEGEDLY THE PATIENT UNDERWENT HALLUX RIGIDUS CORRECTION WITH CHEILECTOMY AND CARTIVA IMPLANT IN THE LEFT FIRST METATARSOPHALANGEAL JOINT. SHE SUBSEQUENTLY WAS REVISED DUE TO ALLEGED PAIN.

    Patient problems: Pain

    MAUDE report 22100893 ↗
  • InjuryJan 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2017 AND THE LEFT SIDE ON (B)(6) 2019. PATIENT ALLEGES HE WAS SCHEDULED FOR A REVISION ON THE RIGHT FOOT FOR (B)(6) 2024. PATIENT ALSO ALLEGES HIS SURGEON RECOMMENDED REVISION ON THE LEFT FOOT AS WELL. PATIENT CLAIMS ONGOING PAIN DUE TO THE IMPLANTS.

    Patient problems: Implant Pain

    MAUDE report 21136791 ↗
  • InjuryJan 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2017 AND THE LEFT SIDE ON (B)(6) 2019. PATIENT ALLEGES HE WAS SCHEDULED FOR A REVISION ON THE RIGHT FOOT FOR (B)(6) 2024. PATIENT ALSO ALLEGES HIS SURGEON RECOMMENDED REVISION ON THE LEFT FOOT AS WELL. PATIENT CLAIMS ONGOING PAIN DUE TO THE IMPLANTS.

    Patient problems: Implant Pain

    MAUDE report 21136790 ↗
  • InjuryJan 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT HE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6)2019. PATIENT HAS NOT BEEN REVISED AND NO PROVIDER HAS RECOMMENDED A REVISION, HOWEVER, THE PATIENT ALLEGES PAIN.

    Patient problems: Implant Pain

    MAUDE report 21135543 ↗
  • InjuryJan 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT THROUGH COUNSEL, THAT HE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON NO DATE GIVEN AND REVISED ON (B)(6) 2024 DUE TO HALLUX LIMITUS. CLAIMANT DEMANDS COMPENSATION.

    Patient problems: Arthritis

    MAUDE report 21124327 ↗
  • InjuryJan 10, 2025Osseointegration Problem; Osseointegration Problem

    IT WAS ALLEGED BY CLAIMANT THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6) 2023 AND REVISED ON (B)(6) 2024 DUE TO SUBSIDENCE. CLAIMANT DEMANDS COMPENSATION.

    Patient problems: Inadequate Osseointegration

    MAUDE report 21124208 ↗
  • InjuryJan 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2018 AND REVISED ON (B)(6) 2022 DUE TO PAIN. CLAIMANT DEMANDS COMPENSATION.

    Patient problems: Pain

    MAUDE report 21109968 ↗
  • InjuryJan 8, 2025Osseointegration Problem; Osseointegration Problem

    IT WAS ALLEGED BY CLAIMANT THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2018 AND REVISED ON (B)(6) 2023 DUE TO PAIN AND SUBSIDENCE. CLAIMANT DEMANDS COMPENSATION.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 21107710 ↗
  • InjuryJan 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT, THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6) 2021. PATIENT HAS NOT BEEN REVISED BUT A MEDICAL PROVIDER HAS RECOMMENDED REVISION DUE TO AN UNSPECIFIED PRODUCT FAILURE. PATIENT DEMANDS COMPENSATION.

    Patient problems: Failure of Implant

    MAUDE report 21107655 ↗
  • InjuryJan 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT, THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2018. PATIENT HAS NOT BEEN REVISED AND HAS NOT BEEN RECOMMENDED FOR REVISION, YET CLAIMS DAMAGES DUE TO PAIN. PATIENT DEMANDS COMPENSATION.

    Patient problems: Discomfort; Pain

    MAUDE report 21107584 ↗
  • InjuryJan 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT, THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6) 2020. PATIENT HAS NOT BEEN REVISED BUT A MEDICAL PROVIDER HAS RECOMMENDED REVISION. PATIENT ALLEGES PAIN AND A COMPLETE LOSS OF MOBILITY IN HER TOE DUE TO THE IMPLANT. PATIENT DEMANDS COMPENSATION.

    Patient problems: Discomfort; Implant Pain; Loss of Range of Motion

    MAUDE report 21107581 ↗
  • InjuryJan 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT, THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2018. PATIENT HAS NOT BEEN REVISED, YET CLAIMS THAT SHE WAS INDICATED FOR A REVISION SURGERY DUE TO PAIN, A SHORTENED TOE, AND A LACK OF MOBILITY. PATIENT DEMANDS COMPENSATION.

    Patient problems: Discomfort; Loss of Range of Motion; Pain; Physical Asymmetry

    MAUDE report 21107574 ↗
  • InjuryJan 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS ALLEGED BY CLAIMANT, THROUGH COUNSEL,THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2023 AND REVISED ON 12/18/2023 DUE TO UNSPECIFIED PRODUCT FAILURE. CLAIMANT DEMANDS COMPENSATION.

    Patient problems: Failure of Implant

    MAUDE report 21107389 ↗
  • InjuryJan 8, 2025Osseointegration Problem; Loosening of Implant Not Related to Bone-Ingrowth; Implant subsidence; Osseointegration Problem; Loosening of Implant Not Related to Bone-Ingrowth; Implant subsidence

    IT WAS ALLEGED BY CLAIMANT, THROUGH COUNSEL, THAT SHE WAS IMPLANTED WITH CARTIVA ON THE RIGHT SIDE ON (B)(6) 2019 AND REVISED ON (B)(6) 2024 DUE TO PAIN, A LOOSE CARTIVA IMPLANT, AND SUBSIDENCE. CLAIMANT DEMANDS COMPENSATION.

    Patient problems: Discomfort; Failure of Implant; Inadequate Osseointegration; Pain

    MAUDE report 21107384 ↗
  • InjuryJan 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CLAIMANT, THROUGH COUNSEL, ALLEGES THAT HE WAS IMPLANTED WITH CARTIVA ON THE LEFT SIDE ON (B)(6) 2018 AND REVISED ON (B)(6) 2022 DUE TO PAIN.

    Patient problems: Implant Pain

    MAUDE report 21100517 ↗

Other Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant devices

All Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant devices →