Skip to content

KneeAlign 2 401587Recalls & reported problems

Orthalign, Inc. · Adjustable Resection Stylus · Class 2

All models of KneeAlign 2 (8)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00858704006237), received between Aug 18, 2023 and Aug 18, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 18, 2023Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    THE SURGEON REPORTED THE RESECTION STYLUS MEASURED "INCORRECTLY" AND THAT THE DEVICE MAY BE "FLEXED WHEN INSERTED INTO THE CUTTING BLOCK.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17577733 ↗

Other Orthopedic Stereotaxic Instrument devices

All Orthopedic Stereotaxic Instrument devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page