OrthAlign Plus 403001Recalls & reported problems

Orthalign, Inc. · OrthAlign Plus Unit · Class 2

All models of OrthAlign Plus (13)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00858704006534), received between Nov 8, 2017 and Oct 12, 2023 — classified as 3 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Communication or Transmission Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Communication or Transmission Problem1
  • Device Sensing Problem1
  • Incorrect Measurement1
  • Incorrect, Inadequate or Imprecise Result or Readings1

Patient problems

  • Bone Fracture(s)2
  • No Clinical Signs, Symptoms or Conditions2
  • Joint Laxity1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 12, 2023Incorrect Measurement; Incorrect Measurement

    EVERYTHING CALIBRATED FINE, BUT THE CUT ON THE FEMUR WAS SIGNIFICANTLY OFF. THE SURGERY WAS COMPLETED WITH STANDARD INSTRUMENTS.

    Patient problems: Joint Laxity

    MAUDE report 17920461 ↗
  • MalfunctionOct 29, 2021Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT THE SUMMARY SCREEN FLEXION EXTENSION NUMBERS DID NOT MATCH THE PREVIOUS ORIGINALLY REGISTERED FLEXION EXTENSION NUMBERS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12719478 ↗
  • MalfunctionAug 5, 2021Communication or Transmission Problem; Communication or Transmission Problem

    AN ORTHALIGN PLUS NAVIGATION UNIT SET THE DISTAL FEMORAL VALGUS ANGLE SO FAR OFF THAT IT'S BEEN VISIBLY INCORRECT FROM A DISTANCE (15 DEGREES OR MORE). REP CHECKED AND ASSISTED NURSE WITH SET UP AND CALIBRATION, ALL STEPS FOLLOWED AS PER TECHNIQUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12285342 ↗
  • MalfunctionMay 16, 2018Device Sensing Problem; Adverse Event Without Identified Device or Use Problem; Device Sensing Problem; Adverse Event Without Identified Device or Use Problem

    ORTHALIGN NAVIGATION UNIT SHOWED A SYSTEM FAULT 6 DURING CALIBRATION, PRIOR TO PATIENT USE. WHEN OBTAINING THE CUP ANGLE THE NAVIGATION UNIT SCREEN DISPLAYED "SYSTEM UNSTABLE" AND WOULD NOT DISPLAY ANGLES. WHEN OBTAINING LEG LENGTH THE NAVIGATION UNIT DISPLAYED A MEASUREMENT OF 141 MM SHORTER AT THE END OF THE CASE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7520582 ↗
  • InjuryNov 8, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SURGEON REPORTED THAT A FRACTURE IN THE TIBIA OCCURRED DURING PLACEMENT OF THE TIBIAL CUTTING BLOCK DURING AN UNICOMPARTMENTAL KNEE ARTHROPLASTY PROCEDURE NAVIGATED BY THE ORTHALIGN PLUS SYSTEM. THE FRACTURE REQUIRED USE OF A SMALL FRAGMENT PLATE AND SCREWS TO STABILIZE THE PROXIMAL TIBIA BELOW THE RESECTION SITE.

    Patient problems: Bone Fracture(s)

    MAUDE report 7012102 ↗
  • InjuryNov 8, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SURGEON REPORTED THAT A PATIENT WHO HAD UNDERGONE AN UNICOMPARTMENTAL KNEE ARTHROPLASTY PROCEDURE NAVIGATED BY THE ORTHALIGN PLUS SYSTEM RETURNED THREE AND A HALF MONTHS LATER WITH A FRACTURE IN THE TIBIA BELOW THE TIBIAL RESECTION. THE FRACTURE REQUIRED A REVISION PROCEDURE WITH A LONG TIBIAL STEM TO CONSTRAIN THE ARTHROPLASTY COMPONENTS AND BYPASS THE FRACTURE SITE.

    Patient problems: Bone Fracture(s)

    MAUDE report 7011820 ↗

Other Orthopedic Stereotaxic Instrument devices

All Orthopedic Stereotaxic Instrument devices →