SafeSept Transseptal Guidwire SS-135Recalls & reported problems

Ppmdm · 0.014" Transseptal guidewire. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00858769006104), received between May 22, 2026 and May 22, 2026 — classified as 1 death.

The most frequently reported specific device problem is “Positioning Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure1

Patient problems

  • Cardiac Tamponade1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • DeathMay 22, 2026Positioning Failure

    IT WAS REPORTED THAT DURING A VT PROCEDURE, THE AORTA WAS PERFORATED BY THE NON-ABBOTT WIRE (SAFESEPT) WHICH REQUIRED SURGERY AND THE PATIENT SUBSEQUENTLY DIED. THE PATIENT WAS HIGH RISK AND HAD MULTIPLE MORBIDITIES. DURING TRANSSEPTAL PUNCTURE WITH THE AGILIS SHEATH, BRK NEEDLE, AND A NON-ABBOTT (SAFESEPT WIRE), THE PHYSICIAN PUNCTURED THE AORTA WITH THE SAFESEPT. HE IMMEDIATELY PULLED BACK THE WIRE. HE TRIED AGAIN AND THIS TIME THE PUNCTURE WAS RIGHT, BUT HE COULD NOT PUSH THE AGILIS DILATOR OVER THE HOLE. HE THEN TRIED A 3RD TIME AND WAS ABLE TO DO A SUCCESSFUL TRANSSEPTAL PUNCTURE. AFTER ADVANCING THE ADVISOR HD GRID CATHETER THROUGH THE AGILIS SHEATH IN THE LV HE ASKED THE ATTENDING CO PHYSICIAN TO DO A CARDIAC ULTRASOUND. THEREBY A PERICARDIAL EFFUSION WAS DIAGNOSED. BLOOD PRESSURE DROPPED TO 60/30. A PERICARDIOCENTESIS WAS PERFORMED AND THE REANIMATION TEAM AND CHIEF PHYSICIANS AND HEART SURGERY WERE CONTACTED. THE CHIEF OF EP TOOK OVER AND WAS ABLE TO PULL OUT LARGE AMOUNTS OF BLOOD. BLOOD PRESSURE STABILIZED TO 120/80. THE PHYSICIAN COULD NOT NO LONGER REMOVE ANY MORE BLOOD. PROTAMIN WAS GIVEN, HOWEVER THE PERICARDIUM WAS FILLING AGAIN WITH BLOOD, WHICH CLOTTED AND WAS NOT

    Patient problems: Cardiac Tamponade

    MAUDE report 25255208 ↗