SafeSept Transseptal Guidwire SS-135Recalls & reported problems
Ppmdm · 0.014" Transseptal guidewire. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00858769006104), received between May 22, 2026 and May 22, 2026 — classified as 1 death.
The most frequently reported specific device problem is “Positioning Failure” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Positioning Failure1
Patient problems
- Cardiac Tamponade1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathMay 22, 2026Positioning Failure
IT WAS REPORTED THAT DURING A VT PROCEDURE, THE AORTA WAS PERFORATED BY THE NON-ABBOTT WIRE (SAFESEPT) WHICH REQUIRED SURGERY AND THE PATIENT SUBSEQUENTLY DIED. THE PATIENT WAS HIGH RISK AND HAD MULTIPLE MORBIDITIES. DURING TRANSSEPTAL PUNCTURE WITH THE AGILIS SHEATH, BRK NEEDLE, AND A NON-ABBOTT (SAFESEPT WIRE), THE PHYSICIAN PUNCTURED THE AORTA WITH THE SAFESEPT. HE IMMEDIATELY PULLED BACK THE WIRE. HE TRIED AGAIN AND THIS TIME THE PUNCTURE WAS RIGHT, BUT HE COULD NOT PUSH THE AGILIS DILATOR OVER THE HOLE. HE THEN TRIED A 3RD TIME AND WAS ABLE TO DO A SUCCESSFUL TRANSSEPTAL PUNCTURE. AFTER ADVANCING THE ADVISOR HD GRID CATHETER THROUGH THE AGILIS SHEATH IN THE LV HE ASKED THE ATTENDING CO PHYSICIAN TO DO A CARDIAC ULTRASOUND. THEREBY A PERICARDIAL EFFUSION WAS DIAGNOSED. BLOOD PRESSURE DROPPED TO 60/30. A PERICARDIOCENTESIS WAS PERFORMED AND THE REANIMATION TEAM AND CHIEF PHYSICIANS AND HEART SURGERY WERE CONTACTED. THE CHIEF OF EP TOOK OVER AND WAS ABLE TO PULL OUT LARGE AMOUNTS OF BLOOD. BLOOD PRESSURE STABILIZED TO 120/80. THE PHYSICIAN COULD NOT NO LONGER REMOVE ANY MORE BLOOD. PROTAMIN WAS GIVEN, HOWEVER THE PERICARDIUM WAS FILLING AGAIN WITH BLOOD, WHICH CLOTTED AND WAS NOT
Patient problems: Cardiac Tamponade
MAUDE report 25255208 ↗
Other Trocar devices
- BRK™ G407208St. Jude Medical Cardiovascular Division · Trocar3 deaths75 reports
- BRK™ 407200St. Jude Medical Cardiovascular Division · Trocar4 deaths71 reports
- NA EP003994SMedtronic, Inc. · Trocar60 reports
- Cook G02364Cook Incorporated · Trocar1 recall5 reports
- HeartSpan® 00884450489345Merit Medical Systems, Inc. · Trocar1 recall1 death2 reports
- Cook G01377Cook Incorporated · Trocar1 recall2 reports
- Cook G02365Cook Incorporated · Trocar1 recall0 reports
- Endrys G19261Cook Incorporated · Trocar1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.