HELIPAQ CERECYTE CHE180308-30Recalls & reported problems
Medos International Sàrl · HELIPAQ microcoil HELIPAQ 18 CERECYTE Coil 3mm x 8cm 190cm Contents: 1 Detachable Coil System · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00878528000716), received between Jan 28, 2020 and Jan 28, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Separation Failure” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Separation Failure1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 28, 2020Separation Failure; Separation Failure
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE PROCEDURE, THE 3MM X 8CM HELIPAQ 18 CERECYTE COIL (CHE18030830 / S11374) DID NOT DETACH. THE COIL WAS SUCCESSFULLY REMOVED FROM THE PATIENT STILL ATTACHED TO THE DELIVERY SYSTEM. THE COIL WAS NOT STRETCHED WHEN IT WAS REMOVED. IT WAS REPORTED THAT A PRE-DEPLOYMENT ELECTRICAL CHECK WAS PERFORMED. THE LOW BATTERY LIGHT AND THE FAULT LIGHT WERE NOT SEEN DURING THE CASE. THE GREEN SYSTEM READY LIGHT ILLUMINATED WHEN THE POWER BUTTON WAS PRESSED; THE AUDIBLE SIGNAL BEEP WAS HEARD WHEN THE DETACHMENT CYCLE WAS INITIATED. ALL THE CONNECTIONS WERE REPORTED TO FIT PROPERLY WITHOUT APPLICATION OF EXCESSIVE FORCE. A NEW CABLE WAS REPLACED BEFORE ANOTHER COIL WAS REPLACED BUT THE 3MM X 8CM HELIPAQ 18 CERECYTE COIL STILL WOULD NOT DETACH. ANOTHER COIL WAS USED, AND EVERYTHING WENT WELL. THE CONTROL CABLE AND THE DETACHMENT CONTROL BOX WAS USED TO DETACH SUBSEQUENT COILS. THE REPORTED ISSUE DID NOT RESULT IN ANY SIGNIFICANT PROCEDURAL DELAY. THERE WAS NO REPORT OF ANY PATIENT ADVERSE EVENT OR COMPLICATION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9638483 ↗
Other DEVICE, NEUROVASCULAR EMBOLIZATION devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.