AMS 700 CX 72404173Recalls & reported problems

Boston Scientific Corporation · Inflatable Penile Prosthesis, 2 Cylinders, InhibiZone treated · Class 3 · Implant

All models of AMS 700 CX (6)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00878953003276), received between Dec 1, 2020 and Oct 15, 2025 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Component Missing” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Component Missing1
  • Fluid/Blood Leak1
  • Mechanical Problem1
  • Migration1

Patient problems

  • Erosion2
  • Capsular Contracture1
  • No Consequences Or Impact To Patient1
  • Perforation1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 15, 2025Fluid/Blood Leak; Mechanical Problem; Fluid/Blood Leak; Mechanical Problem

    IT WAS REPORTED THAT THE PATIENT WITH THIS INFLATABLE PENILE PROSTHESIS (IPP) WAS EXPERIENCING A MECHANICAL ISSUE. DURING THE PROCEDURE, FLUID LOSS WAS IDENTIFIED IN THE RIGHT CYLINDER. BOTH THE OUTER SILICONE WALL AND THE INNER DACRON LAYER WERE FOUND TO BE RUPTURED. THE CYLINDER WAS DIFFICULT TO REMOVE AS TISSUE HAD BECOME INCORPORATED BETWEEN THE LAYERS, WHICH CAUSED ADDITIONAL DAMAGE DURING REMOVAL. ALL COMPONENTS WERE REPLACED, AND THE DEVICE WAS DISPOSED. THERE WERE NO FURTHER PATIENT COMPLICATIONS REPORTED.

    Patient problems: Capsular Contracture

    MAUDE report 23294381 ↗
  • InjuryApr 22, 2022Migration; Migration

    IT WAS REPORTED THAT THE PATIENT PRESENTED TO THEIR PHYSICIAN WITH A PENILE DEFORMITY RELATED TO THIS INFLATABLE PENILE PROSTHESIS (IPP). UPON EXAMINATION, IT WAS DETERMINED THAT THE LEFT CYLINDER HAD MIGRATED AND EXTRUDED THROUGH THE CAVERNOSUM AT THE SITE OF THE CORPOROTOMY. IT WAS NOTED THAT THE CYLINDER STILL INFLATED AS EXPECTED, BUT WAS SITTING UNDER THE SKIN RATHER THAN WITHIN THE CAVERNOSUM. THE PATIENT HAS BEEN SCHEDULED FOR A PROCEDURE ON A FUTURE DATE TO SURGICALLY ADDRESS THE ISSUE. NO ADDITIONAL PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: Erosion; Perforation

    MAUDE report 14190602 ↗
  • InjuryOct 8, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A SURGICAL PROCEDURE TO REMOVE THIS INFLATABLE PENILE PROSTHESIS (IPP) DUE TO SCROTAL INFECTION AND EROSION; IT WAS NOTED THE PUMP COULD BE VISUALIZED OUTSIDE THE SCROTUM. THE IPP WAS EXPLANTED AND REPLACED WITH A TACTRA MALLEABLE PROSTHESIS. THE PATIENT FULLY RECOVERED.

    Patient problems: Erosion; Unspecified Infection

    MAUDE report 12600641 ↗
  • MalfunctionDec 1, 2020Component Missing; Component Missing

    IT WAS REPORTED THAT UPON OPENING PACKAGE, THEY REALIZED IT WAS CYLINDERS ONLY WITHOUT A PRE-ATTACHED MS PUMP. PHYSICIAN WANTED A PRE-ATTACHED SYSTEM. THE PROCEDURE WAS COMPLETED WITH ANOTHER DEVICE WITHOUT PATIENT COMPLICATIONS RELATED O DEVICE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10927028 ↗

Other Prosthesis, Penis, Inflatable devices

All Prosthesis, Penis, Inflatable devices →