AMS 700 CXR MS Pump 72404266Recalls & reported problems

Boston Scientific Corporation · Inflatable Penile Prosthesis, Preconnect Infrapubic, 1 Pump to 2 Cylinders · Class 3 · Implant

All models of AMS 700 CXR MS Pump (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00878953003740), received between Oct 17, 2018 and Sep 11, 2026 — classified as 7 injuries.

The most frequently reported specific device problem is “Mechanical Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Problem3
  • Inadequacy of Device Shape and/or Size2
  • Air/Gas in Device1
  • Defective Device1
  • Degraded1
  • Material Puncture/Hole1
  • Migration1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Discomfort1
  • No Known Impact Or Consequence To Patient1
  • Perforation1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjurySep 11, 2026Mechanical Problem; Material Puncture/Hole; Air/Gas in Device

    It was reported that the pump of an Inflatable Penile Prosthesis (IPP) stopped working, and air was observed during a computed tomography (CT) scan. A surgical procedure was performed, during which a crack in tubing was observed. As a result, the IPP was removed and replaced. No patient complications were reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50725311 ↗
  • InjuryJun 1, 2026Mechanical Problem; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT A PATIENT WITH AN INFLATABLE PENILE PROSTHESIS (IPP) STATED THAT THE DEVICE WAS NOT FUNCTIONING AS WELL AS EXPECTED AND WAS CAUSING DISCOMFORT IN THE PENIS. UPON EXAMINATION, IT WAS DETERMINED THAT THE DEVICE WAS NOT THE APPROPRIATE SIZE, AS IT WAS NOT POSITIONED WITHIN THE GLANS AT THE MEATUS. AS A RESULT, THE CYLINDERS WERE REMOVED AND REPLACED. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: Discomfort

    MAUDE report 25353405 ↗
  • InjuryDec 10, 2024Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT THE PATIENT WITH THIS INFLATABLE PENILE PROSTHESIS (IPP) WAS NOT SATISFIED WITH THE LENGTH OF THE IMPLANT, IT DID NOT REACH THE GLANS. THE IPP WAS REMOVED AND REPLACED WITH LONGER CYLINDERS. THERE WERE NO PATIENT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20892943 ↗
  • InjurySep 11, 2024Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT THE PATIENT HAD A SURGICAL PROCEDURE TO REMOVE THE CYLINDER AND RESERVOIR OF AN INFLATABLE PENILE PROSTHESIS (IPP) DUE TO THE PUMP NOT BEING ABLE TO BE USED. THE CYLINDER WAS INFLATED AND A DEACTIVATION KIT WAS USED TO MAKE THE DEVICE A TACTRA DEVICE. THE PATIENT IS EXPECTED TO FULLY RECOVER FOLLOWING THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20196190 ↗
  • InjuryMar 11, 2021Degraded; Degraded

    IT WAS REPORTED THAT THE PATIENT HAD THE INFLATABLE PENILE PROSTHESIS REMOVED DUE TO CYLINDER ANEURYSM. A NEW INFLATABLE PENILE PROSTHESIS WAS IMPLANTED. NO FURTHER COMPLICATIONS WERE REPORTED IN RELATION TO THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11464140 ↗
  • InjuryApr 11, 2019Defective Device; Defective Device

    IT WAS REPORTED THE PATIENT UNDERWENT AN INFLATABLE PENILE PROSTHESIS (IPP) REVISION SURGERY DUE TO AN UNSPECIFIED MALFUNCTION. THE EXISTING CYLINDERS AND PUMP COMPONENTS WERE EXPLANTED AND REPLACED WITH NEW COMPONENTS. THE EXISTING RESERVOIR REMAINS IMPLANTED IN THE PATIENT. THE EXPLANTED COMPONENTS ARE NOT EXPECTED TO BE RETURNED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, OR PRODUCT BE RETURNED, A SUPPLEMENTAL REPORT WILL BE FILED UPON COMPLETION OF THE PRODUCT ANALYSIS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8505578 ↗
  • InjuryOct 17, 2018Migration; Migration

    IT WAS REPORTED THAT THE PATIENT HAD AN INFLATABLE PENILE PROSTHESIS EXPLANTED AND REPLACED WITH A 14CMX9.5MM DUE TO THE CYLINDERS CROSSED OVER MID SHAFT AND THE RIGHT CYLINDER WAS CROSSED OVER INTO THE LEFT CORPORA. NO FURTHER PATIENT COMPLICATIONS WERE REPORTED IN RELATION TO THIS EVENT.

    Patient problems: Perforation

    MAUDE report 7974488 ↗

Other Prosthesis, Penis, Inflatable devices

All Prosthesis, Penis, Inflatable devices →