Rear Tip Extender 72404323Recalls & reported problems

Boston Scientific Corporation · Non-Stackable Rear Tip Extenders for AMS 700 CX and LGX Cylinders · Class 3 · Implant

All models of Rear Tip Extender (6)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00878953004075), received between Nov 20, 2018 and Aug 9, 2024 — classified as 6 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Inadequacy of Device Shape and/or Size” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Inadequacy of Device Shape and/or Size4
  • Inflation Problem2
  • Collapse1
  • Defective Device1
  • Device Contaminated During Manufacture or Shipping1
  • Insufficient Device Problem Information1
  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Known Impact Or Consequence To Patient3
  • Discomfort1
  • Erosion1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 9, 2024Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT THE REAR TIP EXTENDERS OF THIS INFLATABLE PENILE PROSTHESIS (IPP) WERE REPLACED WITH SMALLER ONES DUE TO POTENTIAL EROSION. NO FURTHER PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: Erosion

    MAUDE report 19950077 ↗
  • MalfunctionJul 11, 2023Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT, DURING THE PREPARATION FOR A PENILE PROSTHESIS PROCEDURE, A FOREIGN MATERIAL INSIDE THE STERILE PACKAGING OF THE REAR TIP EXTENDERS (RTES) WAS DETECTED; THEREFORE, THOSE RTES WERE NOT UTILIZED. OTHER RTES WERE USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17302191 ↗
  • InjuryFeb 3, 2023Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INFLATABLE PENILE PROSTHESIS (IPP) REVISION SURGERY DUE TO DISCOMFORT IN THE SCROTUM. UPON EXPLORATION, THE PHYSICIAN DETERMINED THAT THE PATIENT NEEDED SHORTER REAR TIP EXTENDERS (RTES), THEREFORE THE RTES WERE REMOVED AND REPLACED. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: Discomfort

    MAUDE report 16292501 ↗
  • InjuryApr 20, 2022Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INFLATABLE PENILE PROSTHESIS (IPP) REVISION SURGERY IN WHICH THE RIGHT REAR TIP EXTENDER, WHICH WAS TOO LONG, WAS REMOVED AND REPLACED WITH A SHORTER ONE. NO FURTHER INFORMATION WAS PROVIDED. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14160956 ↗
  • MalfunctionMar 29, 2021Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE PATIENT WAS SCHEDULED ON (B)(6) 2021 TO HAVE THE INFLATABLE PENILE PROSTHESIS REPLACED AS AFTER 2 YEARS OF IMPLANT. THE DEVICE NEVER SEEMED TO GET TO 100% HARDNESS AND SEEMED TO HAVE LOST SOME LENGTH AND GIRTH. THE ENTIRE PUMP MECHANISM DEFLATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11585246 ↗
  • InjuryMay 4, 2020Collapse; Inflation Problem; Mechanical Problem; Collapse; Inflation Problem; Mechanical Problem

    IT WAS REPORTED THAT THE PATIENT HAD THE INFLATABLE PENILE PROSTHESIS REMOVED DUE TO MALFUNCTION AS THE DEVICE FAILED TO ERECT PROPERLY. NO AIR OR HOLES WERE OBSERVED, BUT THE PUMP BULB STAYED FLAT. A NEW INFLATABLE PENILE PROSTHESIS WAS IMPLANTED, THERE WERE NO PATIENT COMPLICATIONS REPORTED. THE PATIENT WAS STABLE AND THE EVENT RESOLVED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10022443 ↗
  • InjuryFeb 5, 2019Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT THE PATIENT HAD HIS INFLATABLE PENILE PROSTHESIS REAR TIP EXTENDERS (RTE) REMOVED DUE TO A POTENTIAL CROSSOVER LEADING TO A DECREASE IN POTENTIAL GIRTH. DURING THE REVISION SURGERY THE PHYSICIAN FELT THERE WAS NO CROSSOVER AND DOWNSIZED THE RTE TO A TOTAL LENGTH OF 2.5 CM RATHER THAN THE PREVIOUS 3.0 CM INDICATING A SLIGHT BUCKLE WITH THE OLD 3.0 RTE. THE NEW RTE WERE PUT IN AND DESIRED RESULT WAS ACHIEVED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8307488 ↗
  • InjuryNov 20, 2018Defective Device; Insufficient Device Problem Information; Defective Device; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REPLACEMENT SURGERY DUE TO AN UNSPECIFIED REASON. THE PREVIOUS 3.0 CM RTE WAS REMOVED, AND REPLACED WITH 5.0CM RTE. FURTHER INFORMATION WAS REQUESTED AND NOT YET RECEIVED. SHOULD ADDITIONAL RELEVANT DETAILS BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED. ADDITIONAL INFORMATION WAS RECEIVED INDICATING THE 3.0 CM RTE WAS REPLACED WITH THE 5.0 CM RTE BECAUSE THE IMPLANT APPEARED TOO SHORT. NO PATIENT COMPLICATIONS WERE REPORTED DURING THE PROCEDURE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8089878 ↗

Other Prosthesis, Penis, Inflatable devices

All Prosthesis, Penis, Inflatable devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page