VANGUARD KNEE SYSTEM 184762Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of Vanguard Knee System (147)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00880304431638), received between Jan 6, 2020 and Oct 10, 2024 — classified as 3 injuries.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (1 report).
1 FDA recall record name this device's identifier.
16 other recalls cover devices cleared under the same FDA submission (K040770, K171054); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Recalls naming this device
- Apr 17, 2020Terminated
Potential presence of elevated endotoxin levels that exceed the specification limit
Z-2154-2020 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Loosening of Implant Not Related to Bone-Ingrowth1
- Loss of or Failure to Bond1
Patient problems
- Fibrosis2
- Loss of Range of Motion2
- Pain2
- Adhesion(s)1
- Failure of Implant1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryOct 10, 2024Loss of or Failure to Bond; Loosening of Implant Not Related to Bone-Ingrowth; Loss of or Failure to Bond; Loosening of Implant Not Related to Bone-Ingrowth
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Failure of Implant
MAUDE report 20415827 ↗InjuryFeb 25, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING PAIN AND STIFFNESS AND SUBSEQUENTLY UNDERWENT A MANIPULATION UNDER ANESTHESIA APPROXIMATELY SIX MONTHS POST LEFT KNEE ARTHROPLASTY DUE TO ARTHROFIBROSIS.
Patient problems: Adhesion(s); Fibrosis; Loss of Range of Motion; Pain
MAUDE report 9752263 ↗InjuryJan 6, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT WAS EXPERIENCING PAIN AND STIFFNESS AND SUBSEQUENTLY UNDERWENT A MANIPULATION UNDER ANESTHESIA APPROXIMATELY SIX MONTHS POST RIGHT KNEE ARTHROPLASTY DUE TO ARTHROFIBROSIS.
Patient problems: Fibrosis; Loss of Range of Motion; Pain
MAUDE report 9554482 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K040770, K171054. One submission often covers many models, so check the product and lot details in each record.
- Z-0938-2019 · Dec 21, 2018 · TerminatedVanguard Knee System Series-A Standard Patella sizes 34mm Item Number: 184766
- Z-0937-2019 · Dec 21, 2018 · TerminatedVanguard Knee System Series-A Standard Patella sizes 31mm Item Number: 184764
- Z-2289-2018 · May 24, 2018 · TerminatedVanguard Complete Knee System; E1 Vanguard PS Tibial Bearing; Model Numbers EP-183664, EP-183642 Product Usage: The product is intended for use in knee joint replacement arthropla
- Z-2177-2018 · May 18, 2018 · TerminatedBiomet Modular Primary Tibial Tray Implants; Modular Interlok Primary Tray (size 75 mm); Item No. 141215; UDI: (01) 00880304005310 (17) 280306 (10) 385340 Product is used in Total
- Z-2183-2018 · May 11, 2018 · TerminatedVanguard Knee System PS Tibial Bearing, Part Number 183621 Intended for use in knee joint replacement procedures.
- Z-1861-2017 · Feb 17, 2017 · Terminatedvarious polyethylene implants Knees Revision Tibial Tray Systems Oxford Partial Knee Orthopedic Salvage System Vanguard Complete Knee System Vanguard SSK Revision System Biomet Pa
- Z-0698-2012 · Oct 4, 2011 · TerminatedBiomet Series A Thin Patella size 25mm, one peg - 184720 Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee joint patellofe
- Z-0701-2012 · Oct 4, 2011 · TerminatedBiomet Series A Standard Patella size 28mm, three pegs - 184762, Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee joint p
- Z-0700-2012 · Oct 4, 2011 · TerminatedBiomet Series A Standard Patella size 25mm, three pegs - 184760, Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee joint p
- Z-0702-2012 · Oct 4, 2011 · TerminatedBiomet Series A Thin Patella size 28mm, three pegs - 184782, Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee joint patel
- Z-0696-2012 · Oct 4, 2011 · TerminatedBiomet Series A Standard Patella size 25mm, one peg, Part 184700, Sterile, Biomet Orthopedics, Warsaw, IN 46582 Knee joint patellofemorotibial, cemented, polymer/metal/polymer, se
- Z-0704-2012 · Oct 4, 2011 · TerminatedBiomet Series A Asymmetrical Patella size 28mm, three pegs - 184791, Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee. J
- Z-0699-2012 · Oct 4, 2011 · TerminatedBiomet Series A Thin Patella size 25mm, one peg - 184720, Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee joint patellof
- Z-0697-2012 · Oct 4, 2011 · TerminatedBiomet Series A Standard Patella size 28mm, one peg - 184702, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & ACG Knee system. Knee joint patellofemo
- Z-0703-2012 · Oct 4, 2011 · TerminatedBiomet Series A Asymmetrical Patella size 25mm, three pegs - 184790, Sterile, Biomet Orthopedics, Warsaw, IN 46582 For use with Vanguard, Maxim, Ascent & AGC Knee Systems Knee. J
…and 1 more.
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page