COMPRESS DEVICE 178787Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of Compress Device (71)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier.
1 other recall cover devices cleared under the same FDA submission (K112905, K123297, K173411, K183553); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Recalls naming this device
- Aug 21, 2019Class IITerminated
Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue.
Z-0519-2020 · Root cause: Environmental control · Recall details · FDA record ↗
FDA clearance and classification
Cleared through 510(k) K183553 on Jan 22, 2019 (decision: Substantially Equivalent). Submitted by Biomet, Inc. as “Compress and Mini Compress Anti-Rotation Spindles”. The FDA review took 33 days. FDA record ↗
Cleared through 510(k) K173411 on Feb 8, 2018 (decision: Substantially Equivalent). Submitted by Biomet Manufacturing Corp as “Comprehensive Segmental Revision System (SRS)”. The FDA review took 99 days. FDA record ↗
Cleared through Special 510(k) K123297 on Nov 20, 2012 (decision: Substantially Equivalent). Submitted by Biomet Manufactuting Corp. as “Compress Segmental Humeral Replacement System”. The FDA review took 29 days. FDA record ↗
…and 1 more FDA submissions listed for this device.
The FDA regulates product code MBF (prosthesis, shoulder, semi-constrained, metal/polymer, uncemented) under 21 CFR 888.3670 as a Class II device. 21 CFR 888.3670 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K112905, K123297, K173411, K183553. One submission often covers many models, so check the product and lot details in each record.
- Z-0642-2019 · Oct 12, 2018 · TerminatedZimmer Compress Devices and Instruments: Item Number/Item Description 178350 Compress Device Anti-Rotation Spindle 178353 Compress Device Anti-Rotation Spindle 178356 Compress Devi
Common questions about the COMPRESS DEVICE 178787
Has the COMPRESS DEVICE 178787 been recalled?
Yes. 1 FDA recall record names this device's identifier, and the FDA has closed (terminated) it. The recall, Z-0519-2020 (Class II), began on Aug 21, 2019: Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
Is the COMPRESS DEVICE 178787 FDA approved?
It was cleared through 510(k) K112905 on May 24, 2012; its record lists 4 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the COMPRESS DEVICE 178787 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the COMPRESS DEVICE 178787, and is it still sold?
The FDA's device database lists Biomet Orthopedics, LLC as the company responsible for it (brand COMPRESS DEVICE, model 178787). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED devices
- COMPREHENSIVE SHOULDER SYSTEM 113629Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall2 reports
- COMPREHENSIVE SHOULDER SYSTEM 113617Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall1 report
- Comprehensive® Shoulder System 113607Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall1 report
- BIO-MODULAR SHOULDER SYSTEM 113863Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall0 reports
- BIO-MODULAR SHOULDER SYSTEM 113867Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall0 reports
- COPELAND SHOULDER SYSTEM 11-114648Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall0 reports
- COPELAND SHOULDER SYSTEM 11-114641Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall0 reports
- COPELAND SHOULDER SYSTEM 11-114644Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page