Persona® Partial Knee System 42-5580-003-02Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of Persona Partial Knee System (60)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00880304808546), received between May 19, 2020 and Mar 24, 2025 — classified as 3 injuries, 1 malfunction.
2 other recalls cover devices cleared under the same FDA submission (K161592); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
Patient problems
- Pain4
- Swelling/ Edema3
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryMar 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Pain; Swelling/ Edema
MAUDE report 21681111 ↗MalfunctionMar 18, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL KNEE SURGERY. AT THE ONE YEAR FOLLOW UP VISIT, THE PATIENT REPORTED ONGOING PAIN AND SWELLING. THE RIGHT KNEE WAS ASPIRATED AND AN ARTHROSCOPY WAS PERFORMED ON UNKNOWN DATES. SUBSEQUENTLY, THE PATIENT WAS REVISED ON AN UNKNOWN DATE. ATTEMPTS HAVE BEEN MADE AND ALL AVAILABLE INFORMATION HAS BEEN PROVIDED.
Patient problems: Pain; Swelling/ Edema
MAUDE report 21634607 ↗InjuryMar 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A RIGHT KNEE ARTHROPLASTY TO ADDRESS TIBIAL LOOSENING AND PAIN THAT INCREASED WITH WEIGHT-BEARING APPROXIMATELY FOUR (4) YEARS POST-OPERATIVELY. ATTEMPTS HAVE BEEN MADE; HOWEVER, NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: Pain
MAUDE report 18859234 ↗InjuryMay 19, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT REPORTED ONGOING PAIN ONE (1) YEAR FOLLOWING RIGHT KNEE ARTHROPLASTY AND WAS GIVEN COCODAMOL FOR TREATMENT OF PAIN. THE PATIENT LATER UNDERWENT AN ARTHROSCOPIC PROCEDURE APPROXIMATELY TWENTY (20) MONTHS POST-OPERATIVELY TO ADDRESS THE KNEE PAIN THAT HAD NOT YET RESOLVED. ATTEMPTS HAVE BEEN MADE AND NO ADDITIONAL INFORMATION IS AVAILABLE AT THIS TIME.
Patient problems: Pain; Swelling/ Edema
MAUDE report 10072481 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K161592. One submission often covers many models, so check the product and lot details in each record.
- Z-1238-2018 · Nov 29, 2017 · TerminatedPersona Partial Knee spacer block instruments; (1) 8mm block, Model Number: 42-5399-035-08; (2) 9mm block, Model Number:42-5399-035-09; (3) 10mm block, Model Number: 42-5399-035-10
- Z-0349-2018 · Jul 5, 2017 · TerminatedPersona Partial Knee System, Size 8, Finishing Guide
Other PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page