VITALITY® 709M8550Recalls & reported problems
Biomet Spine LLC · Class 2
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00880304868366), received between Oct 3, 2024 and Mar 24, 2025 — classified as 4 injuries.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture2
- Loosening of Implant Not Related to Bone-Ingrowth2
Patient problems
- Pain4
- Inadequate Osseointegration3
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryMar 24, 2025Fracture; Fracture
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
Patient problems: Inadequate Osseointegration; Pain
MAUDE report 21679756 ↗InjuryFeb 19, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT ONE YEAR POST-OPERATIVELY, A PATIENT PRESENTED WITH WORSENING PAIN AND PSEUDOARTHROSIS AT L2-3 AND L5-S1 WITH LOOSE SCREWS BILATERALLY AT S1 AND AT LEFT L2. A REVISION SURGERY WAS PERFORMED WHERE THE SCREWS WERE REMOVED. THE L2 SCREW WAS REPLACED WITH A LARGER DIAMETER SCREW. THE SCREWS COULD NOT BE REPLACED AT S1; INSTEAD, THEY WERE MOVED TO ILIAC BILATERALLY. THIS IS REPORT TWO OF THREE FOR THIS EVENT.
Patient problems: Inadequate Osseointegration; Pain
MAUDE report 21410543 ↗InjuryFeb 19, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT ONE YEAR POST-OPERATIVELY, A PATIENT PRESENTED WITH WORSENING PAIN AND PSEUDOARTHROSIS AT L2-3 AND L5-S1 WITH LOOSE SCREWS BILATERALLY AT S1 AND AT LEFT L2. A REVISION SURGERY WAS PERFORMED WHERE THE SCREWS WERE REMOVED. THE L2 SCREW WAS REPLACED WITH A LARGER DIAMETER SCREW. THE SCREWS COULD NOT BE REPLACED AT S1; INSTEAD THEY WERE MOVED TO ILIAC BILATERALLY. THIS IS REPORT ONE OF THREE FOR THIS EVENT.
Patient problems: Inadequate Osseointegration; Pain
MAUDE report 21410542 ↗InjuryOct 3, 2024Fracture; Fracture
IT WAS REPORTED THAT A PATIENT UNDERWENT A REVISION SURGERY TO REPLACE TWO VITALITY SCREWS THAT FRACTURED DURING A CAR ACCIDENT. THE PATIENT WAS EXPERIENCING PAIN, AND THE SCREWS WERE REMOVED AND REPLACED WITH LARGER SCREWS AT THE S1 VERTEBRA. THIS IS REPORT ONE OF TWO FOR THIS EVENT.
Patient problems: Pain
MAUDE report 20363572 ↗
Other APPLIANCE, FIXATION, SPINAL INTERLAMINAL devices
- EXPEDIUM 179702000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL439 reports
- EXPEDIUM VERSE 199721001Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL227 reports
- XIA 3 48230000Stryker Corporation · APPLIANCE, FIXATION, SPINAL INTERLAMINAL193 reports
- VIPER 186715000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL1 death167 reports
- NA 04.614.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL80 reports
- EXPEDIUM VIPER 196789480Depuy Spine, LLC · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- NA 04.615.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- Arsenal Deformity Spinal Fixation System 47127Alphatec Spine, Inc. · APPLIANCE, FIXATION, SPINAL INTERLAMINAL66 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.