ReSolve® 00884450009864Recalls & reported problems
Merit Medical Systems, Inc. · Class 1
All models of ReSolve (16)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450009864), received between Aug 18, 2021 and Aug 18, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Labelling, Instructions for Use or Training Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Labelling, Instructions for Use or Training Problem1
- Off-Label Use1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 18, 2021Labelling, Instructions for Use or Training Problem; Off-Label Use; Labelling, Instructions for Use or Training Problem; Off-Label Use
THE ACCOUNT ALLEGES THAT A DRAINAGE CATHETER WAS PLACED WITHIN A PATIENT ON (B)(6) 2021. THE PATIENT TOLERATED THE PROCEDURE WELL. NO INJURY TO REPORT. DURING A SCHEDULED DRAINAGE CATHETER REPLACEMENT / FOLLOW-UP APPOINTMENT PROCEDURE ON (B)(6) 2021, THE CATHETER WAS FLUSHED WITH CONTRAST UNDER FLUOROSCOPY, AND A GUIDEWIRE WAS INSERTED FOR THE CATHETER EXCHANGE. WHEN THE PHYSICIAN ATTEMPTED TO REMOVE THE CATHETER, IT WAS OBVIOUS THAT THE ORIGINAL DRAINAGE CATHETER HAD DETACHED WITHIN THE PATIENT'S BILIARY SYSTEM. THE ORIGINAL CATHETER WAS REMOVED, AND A NEW CATHETER WAS PLACED SUCCESSFULLY FOR THE PATIENT. THE DETACHED TIP WAS LEFT WITHIN THE PATIENT'S BILIARY SYSTEM. THE PHYSICIAN STATED THAT THE FOREIGN BODY WOULD PASS NATURALLY THROUGH THE PATIENTS GI TRACK. THE IFU STATES: THE DRAINAGE CATHETER IS NOT INTENDED FOR USE WITHIN THE BILIARY SYSTEM [OPERATOR "USE ERROR"]. NO ADDITIONAL CONSEQUENCES TO REPORT.
Patient problems: Foreign Body In Patient
MAUDE report 12338994 ↗
Other CATHETER, IRRIGATION devices
- Navarre Opti-Drain NOD8LPTBard Access Systems, Inc. · CATHETER, IRRIGATION901 reports
- Navarre NNU8LPTBard Access Systems, Inc. · CATHETER, IRRIGATION736 reports
- BLAKE 2227Ethicon Inc. · CATHETER, IRRIGATION331 reports
- Navarre NNU6LPTBard Access Systems, Inc. · CATHETER, IRRIGATION211 reports
- Navarre Opti-Drain NOD10LPTBard Access Systems, Inc. · CATHETER, IRRIGATION178 reports
- Navarre NNU10LPTBard Access Systems, Inc. · CATHETER, IRRIGATION127 reports
- BLAKE 2233Ethicon Inc. · CATHETER, IRRIGATION114 reports
- Vasoshield VH-5001Maquet Cardiovascular LLC · Catheter, Irrigation1 recall27 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page