ONE Snare® 00884450094891Recalls & reported problems

Merit Medical Systems, Inc. · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450094891), received between Dec 15, 2025 and Dec 15, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Cardiac Perforation1
  • Cardiac Tamponade1
  • Low Blood Pressure/ Hypotension1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 15, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A LEAD EXTRACTION PROCEDURE COMMENCED TO REMOVE A RV LEAD DUE TO FRACTURE. THE LEAD WAS PREPPED WITH A SPECTRANETICS LLD TO PROVIDE TRACTION. BEGINNING WITH A SPECTRANETICS 13F TIGHTRAIL ROTATING DILATOR SHEATH, THE LEAD BROKE NEAR THE SVC COIL. THE TIGHTRAIL WAS REMOVED FROM THE BODY, AND THE DECISION WAS MADE TO SNARE FROM THE GROIN. A GORE MEDICAL 20F DRYSEAL FLEX INTRODUCER SHEATH WAS USED WITH AN ABBOTT AGILIS STEERABLE INTRODUCER. A MERIT MEDICAL ONE SNARE AND MERIT MEDICAL WHOLEY GUIDEWIRE WERE INITIALLY USED FOR SNARING. THE WHOLEY WIRE BROKE, SO THEN USED A BOSTON SCIENTIFIC SUPERSTIFF AMPLATZ GUIDEWIRE TO ATTEMPT TO GRAB THE LEAD. AFTER UNSUCCESSFUL ATTEMPTS TO PULL AND EXTRACT, SNARING CONTINUED WITH THE AMPLATZ WIRE AND MERIT MEDICAL ONE SNARE. THE LEAD WAS PULLED THROUGH THE SHEATH, THE ONE SNARE WAS DISENGAGED, AND WAS RAN OVER BOTH ENDS OF THE WIRE AT THE POINT OF THE LEAD. AFTER SUCCESSFULLY GRASPING THE LEAD, HE PULLED DOWN UNTIL THE LEAD DISLODGED FROM THE VASCULATURE. THE SVC COIL BROKE INTO TWO AND REMAINED IN THE SVC. THE REMAINING PORTION OF THE LEAD BROKE OFF AND STAYED INTACT AT THE DISTAL END. THEN, USING THE ONE SNARE, THE LOOSE END OF THE LEAD WAS PULLED

    Patient problems: Cardiac Perforation; Cardiac Tamponade; Low Blood Pressure/ Hypotension

    MAUDE report 23810469 ↗

Other Device, percutaneous retrieval devices

All Device, percutaneous retrieval devices →