InQwire® Amplatz 00884450239476Recalls & reported problems
Merit Medical Systems, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450239476), received between Dec 12, 2023 and Dec 12, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Frayed” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Frayed1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 12, 2023Material Frayed; Material Frayed
THE ACCOUNT ALLEGES THAT DURING A PFO CLOSURE PROCEDURE, THE GUIDEWIRE BECAME STUCK IN THE PATIENT'S ATRIUM. THE PHYSICIAN ACQUIRED RIGHT ANTEGRADE FEMORAL ACCESS AND SUCCESSFULLY ADVANCED AN MPA1 GUIDE CATHETER INTO THE PATIENT'S LEFT ATRIUM. DURING GUIDEWIRE MANIPULATIONS, THE WIRE BECAME STUCK WITHIN THE PATIENT'S PULMONARY ARTERY. THE PATIENT WAS TRANSFERRED TO THE SURGICAL UNIT FOR POSSIBLE INTERVENTIONS. THE CARDIAC INTERVENTIONAL TEAM WAS ON STANDBY AS THE CLINICIAN VIGOROUSLY REMOVED THE FRAYED GUIDEWIRE. NO PATIENT INJURIES OR INTERVENTIONAL CONSEQUENCES TO REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18314756 ↗
Other WIRE, GUIDE, CATHETER devices
- HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II 1009664Abbott Vascular Inc. · WIRE, GUIDE, CATHETER321 reports
- SYNCHRO 14 M00313010Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls220 reports
- PressureWire™ C12059Lightlab Imaging, Inc. · WIRE, GUIDE, CATHETER1 death296 reports
- SYNCHRO 2 M00326410Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls155 reports
- ENROUTE .014" Guidewire 11686-01Silk Road Medical, Inc. · Wire, Guide, Catheter2 deaths228 reports
- ARROW IPN035915Teleflex Incorporated · WIRE, GUIDE, CATHETER217 reports
- OmniWire Pressure guide wire 89185Philips Image Guided Therapy Corporation · Wire, Guide, Catheter1 recall1 death160 reports
- ARROW IPN055780Teleflex Incorporated · Wire, guide, catheter4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page