Skip to content

EMPOWER™ 00884450269206Recalls & reported problems

Merit Medical Systems, Inc. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450269206), received between Jul 2, 2025 and Jul 2, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • No Apparent Adverse Event1
  • Patient Device Interaction Problem1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 2, 2025No Apparent Adverse Event; Patient Device Interaction Problem; No Apparent Adverse Event; Patient Device Interaction Problem

    THE ACCOUNT ALLEGES THAT DURING AN THE EXTRACTION PROCEDURE AFTER A DUAL CHAMBER TRANSVENOUS ICD, THE LEADLESS PACEMAKER WAS NOT ABLE TO BE SNARED BY THE RETRIEVAL SYSTEM WITH EITHER THE SINGLE OR MULTI-LOOP SNARES, DUE TO SUSPECTED ENCAPSULATION OF THE DEVICE. THEREFORE, THE LEADLESS PACEMAKER (LCP) WAS PROGRAMMED OFF AND WAS ABANDONED. IT WAS NOTED THE PROCEDURE WAS PROLONGED BY AT LEAST AN HOUR WITH THE UNSUCCESSFUL EFFORTS TO RETRIEVE THE LCP. NO ADVERSE PATIENT EFFECTS WERE REPORTED. MULTIPLE ATTEMPTS AT SNARING THE EMPOWER PACEMAKER WERE ATTEMPTED WITH BOTH THE SINGLE AND MULTI-LOOP SNARES. PROCEDURE WAS ABANDONED.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 22384430 ↗

Other Device, percutaneous retrieval devices

All Device, percutaneous retrieval devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page