Impress® 00884450295922Recalls & reported problems
Merit Medical Systems, Inc. · Class 2
All models of Impress (145)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450295922), received between Sep 24, 2018 and Sep 24, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Activation, Positioning or Separation Problem1
- Migration or Expulsion of Device1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 24, 2018Migration or Expulsion of Device; Activation, Positioning or Separation Problem
PATIENT CAME TO HOSPITAL FOR A PROCEDURE TO COIL AN ENDOLEAK OF AN ENDOVASCULAR ABDOMINAL AORTIC ANEURYSM. THE PATIENT HAD FEMORAL ACCESS. THE SURGEON INTRODUCED THE VANSCHIE 5 CATHETER OVER A WIRE AND WAS POSITIONING THE CATHETER TO REACH THE LEAKING POINT. UNDER FLUOROSCOPY HE NOTICED THE WIRE WAS NOT OUT THE END OF THE CATHETER. HE PULLED CATHETER AND WIRE OUT OF THE PATIENT AND THE TIP OF THE CATHETER SAILED DOWNSTREAM AND RESTED ON THE SHEATH THAT WAS IN THE LEFT GROIN. THE PATIENT THEN REQUIRED GENERAL ANESTHESIA AND A FEMORAL CUTDOWN TO RETRIEVE THE CATHETER TIP. THE TIP WAS RETRIEVED. THE PATIENT REMAINED IN THE ICU FOR 48 HOURS FOR OBSERVATION. THE INTENDED PROCEDURE WAS ABORTED.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 7901397 ↗
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page