Impress® 00884450654538Recalls & reported problems

Merit Medical Systems, Inc. · Class 2

All models of Impress (145)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00884450654538), received between Jul 17, 2024 and Aug 27, 2025 — classified as 4 injuries, 1 malfunction.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 2 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture4
  • Material Separation2
  • Unable to Obtain Readings2
  • Break1
  • Display or Visual Feedback Problem1
  • Material Integrity Problem1
  • Separation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Foreign Body In Patient1
  • High Blood Pressure/ Hypertension1
  • Obstruction/Occlusion1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 27, 2025Break; Fracture; Material Integrity Problem; Break; Fracture; Material Integrity Problem

    THE ACCOUNT ALLEGES THAT DURING A VENOUS STENT PROCEDURE, THE CATHETER TIP DETACHED AND MIGRATED TO THE HEART. THIS OCCURRED DURING THE CROSS OVER TO ASSESS THE OPPOSITE SIDE OF THE PATIENT PRIOR TO PLACING THE STENT. THE PATIENT WAS ADMITTED TO THE HOSPITAL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22909979 ↗
  • MalfunctionFeb 5, 2025Unable to Obtain Readings; Unable to Obtain Readings

    THE COMPLAINT ALLEGES THAT A PATIENT HAD REPEATED HIGH BLOOD PRESSURE MEASUREMENTS THAT COULD NOT BE CONFIRMED WITH NON-INVASIVE MEASUREMENT TECHNIQUES. THE DISCREPANCY WAS AS HIGH AS 80 MMHG. A SIDE COMPARISON WITH NON-INVASIVE MEASUREMENT RESULTED IN VALUES OF AROUND 120 MMHG SYSTOLIC. EXCHANGED THE SET AND THE VALUES NORMALIZED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21318387 ↗
  • InjuryFeb 5, 2025Display or Visual Feedback Problem; Fracture; Unable to Obtain Readings; Display or Visual Feedback Problem; Fracture; Unable to Obtain Readings

    THE COMPLAINT ALLEGES THAT A PATIENT HAD MASSIVELY ELEVATED BLOOD PRESSURE WHILE LYING FOR A LONG TIME (>300 MMHG SYSTOLIC), ANTI HYPERTENSIVE MEDICATION WAS IMMEDIATELY ADMINISTERED AND A TRIP TO THE CT WAS NEEDED TO RULE OUT THE SUSPICION OF A CEREBRAL HEMORRHAGE. WHEN CHANGING THE BLOOD PRESSURE TRANSMISSION TO THE TRANSPORT MONITOR, THE CLINICAL TEAM NOTICED THAT A CONTACT WAS BROKEN. THE NURSING STAFF COULD NOT IDENTIFY THE CAUSE.

    Patient problems: High Blood Pressure/ Hypertension

    MAUDE report 21318386 ↗
  • InjuryNov 14, 2024Fracture; Material Separation; Separation Problem; Fracture; Material Separation; Separation Problem

    THE ACCOUNT ALLEGES THAT A CATHETER TIP LIKELY DETACHED WITHIN A PATIENT DURING A SCHEDULED RIGHT LEG ANGIOGRAM/POSSIBLE ANGIOPLASTY ON (B)(6) 2024. DURING THIS PROCEDURE, THE PHYSICIAN ATTEMPTED TO ACCESS VIA THE RIGHT FEMORAL ARTERY HOWEVER, IT WAS NOTED THAT THE PATIENT HAD SEVERE CALCIFICATION WITHIN THE RIGHT COMMON FEMORAL ARTERY [CFA], SUPERFICIAL FEMORAL ARTERY [SFA], AND THE RIGHT EXTERNAL ILIAC ARTERY [EIA]. THE PHYSICIAN THEN ACQUIRED SECONDARY RETROGRADE LEFT FEMORAL ARTERY ACCESS WITH 6FX45CM SHEATH FOR EXTRA SUPPORT. THE CLINICIAN WAS SUCCESSFUL IN ADVANCING BOTH THE .035 GLIDEWIRE AND 5F CATHETER UNDER FLUOROSCOPY DURING THE RIGHT ILIO-FEMORAL ARTERY CROSSOVER- TECHNIQUE TO ACQUIRE ACCESS TO THE TARGETED RIGHT FEMORAL ARTERY. THE PROCEDURE WAS SUCCESSFULLY COMPLETED AT THIS TIME WITHOUT THE ATTENDING MEDICAL STAFF NOTICING THE ACCIDENTAL IATROGENIC FOREIGN BODY [IFB] INTRODUCTION. THE ANGIOGRAM AND ANGIOPLASTY WERE SUCCESSFULLY PERFORMED ON THE PATIENT'S RIGHT EIA, AND RIGHT SFA. THE PATIENT UNDERWENT A SECONDARY FEMORAL ARTERY ENDARTERECTOMY PROCEDURE ON (B)(6) 2024. THE ATTENDING MEDICAL STAFF NOTED THE IATROGENIC FOREIGN BODY [IFB] THAT WAS INADVERTENTLY LEFT WITH

    Patient problems: Foreign Body In Patient; Obstruction/Occlusion

    MAUDE report 20689679 ↗
  • InjuryJul 17, 2024Fracture; Material Separation; Fracture; Material Separation

    THE ACCOUNT ALLEGES THAT DURING A FEMORO-POPLITEAL STENTING RECANALIZATION PROCEDURE VIA CROSS-OVER TECHNIQUE, WHEN ATTEMPTING TO REMOVE THE CATHETER THE PHYSICIAN NOTED THAT THE TIP OF THE PROBE HAD BECOME LOOSE AND REMAINED ON THE INTRA-ARTERIAL GUIDEWIRE. THE TIP OF THE CATHETER WAS RECOVERED USING A VASCULAR SNARE DEVICE. NO ADDITIONAL PATIENT CONSEQUENCES TO REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19760329 ↗

Other Catheter, intravascular, diagnostic devices

All Catheter, intravascular, diagnostic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page