Impress® 00884450683842Recalls & reported problems
Merit Medical Systems, Inc. · Class 2
All models of Impress (145)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450683842), received between Oct 22, 2024 and Oct 22, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
- Material Separation1
Patient problems
- Foreign Body In Patient1
- Ischemia1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 22, 2024Fracture; Material Separation; Fracture; Material Separation
THE ACCOUNT ALLEGES THAT AN ELDERLY MALE PATIENT PRESENTED WITH AN ISCHEMIC STROKE AND WAS BROUGHT IN FOR A MECHANICAL THROMBECTOMY. THE PHYSICIAN USED A MERIT 4F H1 DIAGNOSTIC CATHETER WITH A TERUMO GUIDE WIRE FOR THIS PROCEDURE. AS SOON AS THE DIAGNOSTIC CATHETER WAS ADVANCED OVER THE TERUMO GUIDEWIRE VIA THE RIGHT FEMORAL ARTERY, THE DIAGNOSTIC CATHETER DETACHED INTO TWO PIECES. THIS WAS VERIFIED UNDER FLUOROSCOPY. THE PHYSICIAN USED A VASCULAR SNARE DEVICE TO RETRIEVE ONE FOREIGN BODY FROM THE PATIENT. THE OTHER FOREIGN BODY MIGRATED INTO THE PATIENT'S ANTERIOR TIB ARTERY. THE PATIENT WILL REQUIRE THE SURGICAL REMOVAL OF THE REMAINING FOREIGN BODY.
Patient problems: Foreign Body In Patient; Ischemia
MAUDE report 20511117 ↗
Other Catheter, intravascular, diagnostic devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H749085263001Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page