Skip to content

Performa® B (REF 7757-2MP65)Recalls & reported problems

Merit Medical Systems, Inc. · Class 2

Adverse event reports
15
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 00884450766507), received between Feb 20, 2025 and Sep 9, 2026 — classified as 2 injuries, 13 malfunctions.

The most frequently reported specific device problem is “Material Separation” (11 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 3 reportsMar 2025: 1 reportsApr 2025: 2 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 3 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 2 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Separation11
  • Fracture6
  • Fluid/Blood Leak3
  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions12
  • Foreign Body In Patient3

Recent adverse event reports

The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 9, 2026Material Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50689685 ↗
  • MalfunctionAug 26, 2026Material Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50459046 ↗
  • MalfunctionAug 13, 2026Material Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50235141 ↗
  • MalfunctionJan 21, 2026Material Separation

    CUSTOMER REPORTS THE CATHETER BROKE DURING PROCEDURE WHEN PRESSURE OF PSI 900 WAS APPLIED. THEY ALLEGE THE END BLEW COMPLETELY OFF. NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24130114 ↗
  • MalfunctionJan 21, 2026Material Separation

    CUSTOMER REPORTS THE CATHETER BROKE DURING PROCEDURE WHEN PRESSURE OF PSI 1000 WAS APPLIED. NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24130020 ↗
  • MalfunctionJan 21, 2026Material Separation

    CUSTOMER REPORTS THE HUB DISCONNECTED FROM CATHETER UPON USE WITH POWER INJECTOR (1100 PSI).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24130016 ↗
  • MalfunctionDec 17, 2025Fracture; Fracture

    THE ACCOUNT ALLEGES THAT DURING A POWER INJECTION AND THE HUB FROM THE CATHETER BROKE OFF. NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23831251 ↗
  • MalfunctionDec 17, 2025Fracture; Fracture

    THE ACCOUNT ALLEGES THAT DURING A POWER INJECTION AND THE HUB FROM THE CATHETER BROKE OFF. NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23830639 ↗
  • MalfunctionJul 16, 2025Break; Fracture; Break; Fracture

    THE ACCOUNT ALLEGES THAT THE CATHETER BROKE AT THE TOP. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22522768 ↗
  • InjuryApr 1, 2025Fluid/Blood Leak; Material Separation; Fluid/Blood Leak; Material Separation

    THE ACCOUNT ALLEGES THAT DURING A PEDIATRIC PROCEDURE, THE DEVICE WAS FOUND TO BE LEAKING FLUID BETWEEN THE HUB AND THE CATHETER CONNECTION, OUTSIDE THE PATIENT'S BODY. NO PATIENT INJURY TO REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21748826 ↗
  • InjuryApr 1, 2025Fluid/Blood Leak; Material Separation; Fluid/Blood Leak; Material Separation

    THE ACCOUNT ALLEGES THAT DURING A PEDIATRIC PROCEDURE, THE DEVICE WAS FOUND TO BE LEAKING FLUID BETWEEN THE HUB AND THE CATHETER CONNECTION, OUTSIDE THE PATIENT'S BODY. NO PATIENT INJURY TO REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21748823 ↗
  • MalfunctionMar 26, 2025Fluid/Blood Leak; Fluid/Blood Leak

    THE ACCOUNT ALLEGES THAT THE DEVICE WAS FOUND TO BE LEAKING AT THE HUB. NO ADDITIONAL PATIENT CONSEQUENCE TO REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21700184 ↗
  • MalfunctionFeb 20, 2025Fracture; Material Separation; Fracture; Material Separation

    THE ACCOUNT ALLEGES THAT THE CATHETER BROKE AT THE HUB DURING A PROCEDURE IN THE HEART. NO PATIENT INJURY WAS REPORTED.

    Patient problems: Foreign Body In Patient

    MAUDE report 21420478 ↗
  • MalfunctionFeb 20, 2025Fracture; Material Separation; Fracture; Material Separation

    THE ACCOUNT ALLEGES THAT THE CATHETER BROKE AT THE HUB DURING A PROCEDURE IN THE HEART. NO PATIENT INJURY WAS REPORTED.

    Patient problems: Foreign Body In Patient

    MAUDE report 21420477 ↗
  • MalfunctionFeb 20, 2025Fracture; Material Separation; Fracture; Material Separation

    THE ACCOUNT ALLEGES THAT THE CATHETER BROKE AT THE HUB DURING A PROCEDURE IN THE HEART. NO PATIENT INJURY WAS REPORTED.

    Patient problems: Foreign Body In Patient

    MAUDE report 21420476 ↗

Other Catheter, intravascular, diagnostic devices

All Catheter, intravascular, diagnostic devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.