Superion Driver N/ARecalls & reported problems
Vertiflex, Inc. · Superion Driver · Class 3
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00884662000123), received between Oct 22, 2018 and Nov 1, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Difficult or Delayed Positioning” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Difficult or Delayed Positioning2
- Material Fragmentation2
Patient problems
- No Known Impact Or Consequence To Patient2
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 1, 2018Difficult or Delayed Positioning; Material Fragmentation; Difficult or Delayed Positioning; Material Fragmentation
DURING ATTEMPTS TO PLACE A SUPERION IDS AT L3/L4, THE DISTAL TIP OF THE MANUAL DRIVER INSTRUMENT BROKE OFF. THE FRAGMENT WAS FIRMLY LODGED IN THE PROXIMAL END OF THE IMPLANT, AND RESISTED THE PHYSICIAN'S EFFORTS TO EXTRACT IT. AS IT WAS FIRMLY ATTACHED TO THE IMPLANT, AND THE IMPLANT WAS CORRECTLY PLACED, THE PHYSICIAN ELECTED TO LEAVE IT IN PLACE AND CLOSE. THE COMPANY REPRESENTATIVE WHO WAS OBSERVING THE CASE REPORTS THAT THE INTERSPINOUS SPACE INTO WHICH THE IMPLANT WAS BEING PLACED WAS "VERY TIGHT" SUCH THAT SIGNIFICANT RESISTANCE TO IMPLANT DEPLOYMENT WAS EXPERIENCED. HE SUGGESTED THAT THE PHYSICIAN APPLIED EXCESSIVE TORQUE TO THE DRIVER TO COMPLETE IMPLANT PLACEMENT, WHICH MAY HAVE EXCEEDED THE STRENGTH OF THE DRIVER, RESULTING IN THE FRACTURE OF THE DISTAL TIP.
Patient problems: Device Embedded In Tissue or Plaque; No Known Impact Or Consequence To Patient
MAUDE report 8029272 ↗MalfunctionOct 22, 2018Difficult or Delayed Positioning; Material Fragmentation; Difficult or Delayed Positioning; Material Fragmentation
DURING ATTEMPTS TO PLACE A SUPERION IDS IMPLANT AT L4/L5, SIGNIFICANT RESISTANCE TO DEPLOYMENT WAS ENCOUNTERED. TO OVERCOME THIS RESISTANCE, EXCESSIVE TORQUE WAS APPLIED BY THE TREATING PHYSICIAN IN AN ATTEMPT TO DEPLOY THE IMPLANT, WITH THE RESULT THAT ONE (1) 10MM IMPLANT WAS BROKEN. THIS IMPLANT WAS SUCCESSFULLY REMOVED WITHOUT ISSUE, AND A SECOND IMPLANTATION ATTEMPTED. WHILE THIS IMPLANT WAS SUCCESSFULLY PLACED, ALBEIT AFTER THE PHYSICIAN USED A MALLET TO FINISH DEPLOYMENT, DURING DEPLOYMENT THE TIP OF THE MANUAL DRIVER INSTRUMENT FRACTURED. A PORTION OF THE FRACTURED TIP REMAINED FIRMLY ENGAGED WITHIN THE DISTAL END OF THE IMPLANT BODY, AND WAS ALLOWED BY THE PHYSICIAN TO REMAIN IN SITU. IT IS NOTABLE THAT THE PATIENT PRESENTED WITH BOTH ANKYLOSIS AND SIGNIFICANT SCOLIOSIS, WHICH ARE BOTH CONTRAINDICATED CONDITIONS, AND WOULD HAVE BEEN THE PROXIMATE CAUSE(S) OF THE RESISTANCE TO DEPLOYMENT ENCOUNTERED. SEVERAL UNSUCCESSFUL ATTEMPTS HAVE BEEN MADE TO CONTACT THE TREATING PHYSICIAN TO DISCUSS THE RAMIFICATIONS OF THE DRIVER FRAGMENT LEFT IN SITU. WE WILL CONTINUE TO ATTEMPT TO FOLLOW UP WITH THE CLINICIAN.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7991718 ↗
Other Prosthesis, Spinous Process Spacer/Plate devices
- Superion™ 101-9812Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate2 recalls810 reports
- Superion™ 101-9810Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate1 recall356 reports
- Superion™ 101-9814Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate2 recalls295 reports
- Superion™ SUI 102-9800Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate2 recalls123 reports
- Superion™ 101-9808Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate2 recalls4 reports
- Vertiflex™ VIP 140-9800Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate1 recall23 reports
- Superion™ 101-9816Boston Scientific Neuromodulation Corporation · Prosthesis, Spinous Process Spacer/Plate1 recall23 reports
- Superion Interspinous Spacer 14mmVertiflex, Inc. · Prosthesis, Spinous Process Spacer/Plate5 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page